Warning What does this mean?

Your system is down or running degraded, but this is not an immediate safety danger. Work through the safe steps below.

SolarEdge Inverter Error 18XA6 — Practical Steps to Fix It Safely

SolarEdge Inverter Error 18XA6 — Practical Steps to Fix It Safely

Your inverter's built-in self-check found an internal hardware fault, so it has stopped producing as a protective measure. These codes all mean the same thing on different SolarEdge displays. Try one full power cycle — if the code comes back, the unit needs professional service.

What should I do first?

Two quick questions — we'll point you to the right starting point.

Is this code still showing on your inverter's display?

What this code means

A SolarEdge inverter runs continuous self-diagnostics on its own electronics. When one of those checks fails, the unit latches a hardware error and halts production deliberately — it would rather stop than operate with a suspected internal fault. This is why the code feels abrupt: there is no gradual warning, just a working system one moment and a stopped one the next.

The different code numbers reflect display and firmware generations, not different problems. On single-phase inverters running CPU v3.19xx firmware the fault shows as 2x10 or 2x95; on newer single-phase displays it appears as 18xA6. SolarEdge's official error table maps every one of these to the same "Hardware Error" condition, with the same remedy.

What the manual does not give you is a homeowner-diagnosable cause — and that absence is itself the message. Unlike a grid-voltage code, there is no external condition to wait out and no setting to adjust. The troubleshooting column for this row simply says to contact SolarEdge support. A one-off failed self-test can occasionally clear after a clean restart, for example after a firmware update or a rough power event, but a fault that survives a proper power cycle is a genuine internal failure.

What is this downtime costing you?

Rough estimate while your system isn't producing. Adjust the numbers to match your setup.

–per day
–per week
–per 30 days

≈ – kWh of lost production per day.

Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.

Common causes

  • A one-off failed self-test after a firmware update or an awkward power event — the hopeful case. The check trips on a transient glitch, and a clean restart clears it for good.
  • Internal electronic component failure. The manual names no specific cause for this row; it is a general flag that something inside the unit failed its checks.
  • Damage from a grid surge or lightning strike. Suspect this more strongly if the code appeared during or just after a storm, especially if other electronics in the home were affected too.
  • A corrupted firmware state after an interrupted update. If the inverter lost power mid-update, the software can be left in a condition that fails its own integrity checks.
  • Age-related electronics failure. Less likely on a young unit, but years of heat cycling eventually wear on internal components, and the self-test is designed to catch exactly that.

Safe steps to try

Work top to bottom, ticking off each step as you complete it. 0 of 5 done.

Is your inverter still under warranty?

Before paying for a repair, check — your installer may fix this free.

Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.

When to call an electrician

The decision point is simple: if the code is still there after one properly done power cycle, or if it clears and then recurs over the following days, stop restarting and get professional help. Contact your installer or SolarEdge support with the code, serial number, and firmware version you recorded. Support can usually run remote diagnostics through your monitoring connection to confirm whether the fault is genuine. If it is, the unit needs service or replacement — SolarEdge inverters carry a 12-year standard warranty (extendable to 20 or 25 years), and your serial number is what confirms your coverage. There is no homeowner setting or reset that resolves a true hardware error, so this is not one to live with.

Frequently asked questions

Will a restart actually fix a hardware error?

Sometimes — a one-off self-test failure after a power event or update can clear with a single clean power cycle. But if the code comes back, the fault is real. Do not keep restarting it; that changes nothing and delays the actual fix.

Is my home safe with this error showing?

Yes. The inverter shut itself down precisely to stay safe, and a stopped inverter is not a hazard. Just do not open the unit or touch any wiring — record the code and arrange service.

Is a hardware error covered by warranty?

Usually, yes. SolarEdge inverters come with a 12-year standard warranty, extendable to 20 or 25 years. Your installer or SolarEdge support can confirm your coverage from the serial number.

My inverter is only a couple of years old — how can the hardware already be faulty?

Early failures happen with any electronics, which is exactly what warranties are for. Surges and interrupted firmware updates can also trigger it on a young unit. Age is only one of several possible causes.

Need a professional?

This fault may need professional diagnosis. Contact a qualified solar electrician in your area.

Sources: meaning and troubleshooting verified against the manufacturer's documentation — Troubleshooting SolarEdge Systems, Addendum (Europe & APAC), MAN-01-00333-1.1 — Hardware Error row (single-phase CPU v3.19xx: 2x10, 2x95; troubleshooting: 'Contact SolarEdge Support'). Also: Single Phase Inverter with HD-Wave Technology Installation Guide, MAN-01-00306-1.1, Appendix A (errors 166-168 → 18xA6-A8: 'HW error. Contact SolarEdge support.').