All Inverter Error Codes

138 diagnostic articles across 11 manufacturers — each one verified against the manufacturer's own documentation.

Deye

9 codes
Deye Inverter Error F02/F24 — DC Insulation Impedance Fault Explained
Critical

Deye Inverter Error F02/F24 — DC Insulation Impedance Fault Explained

F02 and F24 both mean your Deye inverter measured dangerously low insulation resistance between…

Read diagnosis →
Deye Inverter Error F15 — Is It Serious? How to Respond
Warning

Deye Inverter Error F15 — Is It Serious? How to Respond

Error F15 on a Deye inverter is an “AC firmware over current” fault —…

Read diagnosis →
Deye Inverter Error F29 — Parallel CAN Bus Fault Explained
Warning

Deye Inverter Error F29 — Parallel CAN Bus Fault Explained

F29 (Parallel_CANBus_Fault) appears on Deye hybrid inverters running in parallel — two or more…

Read diagnosis →
Deye Inverter Error F35 — No AC Grid Detected
Warning

Deye Inverter Error F35 — No AC Grid Detected

F35 means your Deye inverter cannot detect the AC grid — “no AC grid”…

Read diagnosis →
Deye Inverter F05/F06 — EEPROM Memory Errors Explained
Warning

Deye Inverter F05/F06 — EEPROM Memory Errors Explained

F05 and F06 are internal memory faults: your Deye inverter failed to read (F05)…

Read diagnosis →
Deye Inverter F20 — DC Overcurrent Fault, Causes and Safe Fixes
Critical

Deye Inverter F20 — DC Overcurrent Fault, Causes and Safe Fixes

F20 is a hardware-level DC overcurrent fault: your Deye inverter measured more current on…

Read diagnosis →
Deye Inverter F26 — What a DC Busbar Unbalance Fault Means
Warning

Deye Inverter F26 — What a DC Busbar Unbalance Fault Means

F26 means the DC busbar inside your Deye inverter is unbalanced — the internal…

Read diagnosis →
Deye Inverter F56 — DC Busbar Voltage Too Low at Startup?
Warning

Deye Inverter F56 — DC Busbar Voltage Too Low at Startup?

F56 means the DC busbar voltage inside your Deye inverter is too low. Deye’s…

Read diagnosis →
Deye Inverter Warning W31 — Is Your Battery Still Talking to It?
Warning

Deye Inverter Warning W31 — Is Your Battery Still Talking to It?

W31 (Battery_comm_warn) is a warning — not a shutdown fault — telling you that…

Read diagnosis →

Fronius

22 codes
Fronius Inverter Code 223 — Undervoltage on L2 Explained
Warning

Fronius Inverter Code 223 — Undervoltage on L2 Explained

Fronius code 223 means "Undervoltage at L2-N": the inverter measured the voltage between line…

Read diagnosis →
Fronius Inverter Code 240 — What an Arc Detection Warning Means
Critical

Fronius Inverter Code 240 — What an Arc Detection Warning Means

Code 240 means your Fronius inverter's arc detector found an electric arc in the…

Read diagnosis →
Fronius Inverter Code 241 — Arc Detected, and What Happens Next
Critical

Fronius Inverter Code 241 — Arc Detected, and What Happens Next

Code 241 on a Fronius Symo, Primo, or Galvo means ArcContinuousFault: the inverter's arc-fault…

Read diagnosis →
Fronius Inverter Code 314 — Current Sensor Calibration Timed Out
Warning

Fronius Inverter Code 314 — Current Sensor Calibration Timed Out

Code 314 means your Fronius inverter's routine calibration of its current sensors didn't finish…

Read diagnosis →
Fronius Inverter Code 479 — The Intermediate Circuit Relay Switched Off
Warning

Fronius Inverter Code 479 — The Intermediate Circuit Relay Switched Off

Code 479 means the protection relay on your Fronius inverter's intermediate (DC-link) circuit opened…

Read diagnosis →
Fronius Inverter STATE 102 — What Does It Mean? A Plain-English Guide
Info

Fronius Inverter STATE 102 — What Does It Mean? A Plain-English Guide

STATE 102 means the AC grid voltage is too high. The inverter has disconnected…

Read diagnosis →
Fronius Inverter STATE 103 — Should You Worry?
Info

Fronius Inverter STATE 103 — Should You Worry?

STATE 103 means the AC grid voltage is too low. The inverter has disconnected…

Read diagnosis →
Fronius Inverter STATE 105 — Is Your Grid Frequency Too High?
Info

Fronius Inverter STATE 105 — Is Your Grid Frequency Too High?

STATE 105 means your Fronius inverter measured AC grid frequency above its permitted limit…

Read diagnosis →
Fronius Inverter STATE 106 — Should You Worry?
Info

Fronius Inverter STATE 106 — Should You Worry?

STATE 106 means the grid frequency dropped too low, so your inverter briefly disconnected…

Read diagnosis →
Fronius Inverter STATE 107 — What It Means and When to Worry
Info

Fronius Inverter STATE 107 — What It Means and When to Worry

STATE 107 means the inverter cannot detect the AC grid — it is waiting…

Read diagnosis →
Fronius Inverter STATE 108 — What Does It Mean? A Plain-English Guide
Info

Fronius Inverter STATE 108 — What Does It Mean? A Plain-English Guide

STATE 108 means the inverter detected stand-alone (islanded) operation — it believes the grid…

Read diagnosis →
Fronius Inverter STATE 301 — What an AC Overcurrent Means
Warning

Fronius Inverter STATE 301 — What an AC Overcurrent Means

STATE 301 means your Fronius inverter detected an overcurrent on its AC output and…

Read diagnosis →
Fronius Inverter STATE 306 — Normal Behavior or a Real Problem?
Info

Fronius Inverter STATE 306 — Normal Behavior or a Real Problem?

STATE 306 (LOW PV POWER) means there is not enough sunlight for the inverter…

Read diagnosis →
Fronius Inverter STATE 307 — What It Means and When to Worry
Info

Fronius Inverter STATE 307 — What It Means and When to Worry

STATE 307 (DC LOW) means the DC voltage from your panels is too low…

Read diagnosis →
Fronius Inverter STATE 309 — What It Means & What to Check
Warning

Fronius Inverter STATE 309 — What It Means & What to Check

STATE 309 means the DC input voltage on MPPT 1 is too high —…

Read diagnosis →
Fronius Inverter STATE 447 — A Homeowner’s Troubleshooting Guide
Warning

Fronius Inverter STATE 447 — A Homeowner’s Troubleshooting Guide

STATE 447 is an insulation-fault warning: the inverter's self-diagnosis found that electrical insulation is…

Read diagnosis →
Fronius Inverter STATE 457 — What to Do Next
Warning

Fronius Inverter STATE 457 — What to Do Next

STATE 457 means your Fronius inverter's internal grid relay may be sticking, or the…

Read diagnosis →
Fronius Inverter STATE 461 — What a DSP Memory Fault Means
Warning

Fronius Inverter STATE 461 — What a DSP Memory Fault Means

STATE 461 means your Fronius inverter has detected a fault in the data memory…

Read diagnosis →
Fronius Inverter STATE 475 — Causes and Safe Fixes
Warning

Fronius Inverter STATE 475 — Causes and Safe Fixes

STATE 475 means your Fronius inverter has detected a ground fault on the solar…

Read diagnosis →
Fronius Inverter STATE 502 — Practical Steps to Fix It Safely
Warning

Fronius Inverter STATE 502 — Practical Steps to Fix It Safely

STATE 502 means your Fronius inverter has detected an insulation fault in the solar…

Read diagnosis →
Fronius Inverter STATE 517 — Why It Happens and How to Respond
Warning

Fronius Inverter STATE 517 — Why It Happens and How to Respond

STATE 517 means the inverter is derating — deliberately reducing its power output because…

Read diagnosis →
Fronius Inverter STATE 567 — Normal Behavior or a Real Problem?
Info

Fronius Inverter STATE 567 — Normal Behavior or a Real Problem?

STATE 567 is informational: Grid Voltage Dependent Power Reduction — volt-watt mode — is…

Read diagnosis →

GoodWe

11 codes
GoodWe Inverter Error 14 — What It Means & What to Check
Warning

GoodWe Inverter Error 14 — What It Means & What to Check

GoodWe error 14 (“Isolation Fail”) means the inverter measured the insulation resistance between your…

Read diagnosis →
GoodWe Inverter Error 14 Isolation Fail — Low Insulation Resistance
Critical

GoodWe Inverter Error 14 Isolation Fail — Low Insulation Resistance

Error 14 on a GoodWe inverter means "Isolation Fail": the inverter measured the insulation…

Read diagnosis →
GoodWe Inverter Error 15 — Causes and Safe Fixes
Warning

GoodWe Inverter Error 15 — Causes and Safe Fixes

GoodWe error 15 (“Vac Failure”) means the voltage coming from your electricity grid is…

Read diagnosis →
GoodWe Inverter Error 15 Vac Failure — Grid Voltage Out of Range
Warning

GoodWe Inverter Error 15 Vac Failure — Grid Voltage Out of Range

Error 15 on a GoodWe inverter means "Vac Failure": the AC voltage from your…

Read diagnosis →
GoodWe Inverter Error 16 — External Fan Fault and How to Respond
Warning

GoodWe Inverter Error 16 — External Fan Fault and How to Respond

Error 16 — 'EFan Fault' — means the external cooling fan on your GoodWe…

Read diagnosis →
GoodWe Inverter Error 17 — A Homeowner’s Troubleshooting Guide
Warning

GoodWe Inverter Error 17 — A Homeowner’s Troubleshooting Guide

GoodWe error 17 (“PV Over Voltage”) means the voltage from your solar panels is…

Read diagnosis →
GoodWe Inverter Error 21 — What to Do Next
Warning

GoodWe Inverter Error 21 — What to Do Next

GoodWe error 21 (“DC Bus High”) means the voltage on the inverter's internal DC…

Read diagnosis →
GoodWe Inverter Error 23 — Utility Loss and How to Respond
Warning

GoodWe Inverter Error 23 — Utility Loss and How to Respond

GoodWe error 23 (“Utility Loss”) means your inverter cannot detect the electricity grid —…

Read diagnosis →
GoodWe Inverter Error 30 — What the 1.5V Reference Fault Means
Warning

GoodWe Inverter Error 30 — What the 1.5V Reference Fault Means

Error 30 means the inverter's internal 1.5V reference voltage circuit has failed — GoodWe's…

Read diagnosis →
GoodWe Inverter Error 7 and 25 — Relay Check Failure Explained
Warning

GoodWe Inverter Error 7 and 25 — Relay Check Failure Explained

Errors 7 and 25 both mean 'Relay Check Failure' — the inverter's self-test of…

Read diagnosis →
GoodWe Inverter Errors 18 and 19 — Overheating Causes and Cures
Warning

GoodWe Inverter Errors 18 and 19 — Overheating Causes and Cures

Errors 18 ('Temperature Too High') and 19 ('Over Temperature') are GoodWe's thermal protection codes:…

Read diagnosis →

Growatt

21 codes
Growatt AC V Outrange — What to Do Next
Warning

Growatt AC V Outrange — What to Do Next

AC V Outrange means the grid voltage is outside the range your inverter may…

Read diagnosis →
Growatt Ground I Fault — What It Means and When to Call an Electrician
Critical

Growatt Ground I Fault — What It Means and When to Call an Electrician

Ground I Fault means the inverter measured excessive current on the earth (ground) path…

Read diagnosis →
Growatt Inverter 405 — Is a Relay Fault Serious?
Warning

Growatt Inverter 405 — Is a Relay Fault Serious?

Error 405 means your Growatt inverter's internal grid relay has failed — the relay…

Read diagnosis →
Growatt Inverter AC F Outrange — A Plain-English Frequency Guide
Warning

Growatt Inverter AC F Outrange — A Plain-English Frequency Guide

AC F Outrange means the utility grid’s frequency has moved outside the range your…

Read diagnosis →
Growatt Inverter Auto Test Failed — Why It Happens and What to Do
Warning

Growatt Inverter Auto Test Failed — Why It Happens and What to Do

If your Growatt shows “Auto Test Failed” (Error 407), the inverter’s Italy-only protection self-test…

Read diagnosis →
Growatt Inverter Error 04 — Low Battery Voltage, Causes and Safe Steps
Warning

Growatt Inverter Error 04 — Low Battery Voltage, Causes and Safe Steps

Error 04 on a Growatt SPF off-grid inverter means the battery voltage has fallen…

Read diagnosis →
Growatt Inverter Error 100 — A Homeowner’s Troubleshooting Guide
Warning

Growatt Inverter Error 100 — A Homeowner’s Troubleshooting Guide

Error 100 means the inverter's internal 2.5-volt reference — the baseline every measurement is…

Read diagnosis →
Growatt Inverter Error 101 — Why It Happens and How to Respond
Warning

Growatt Inverter Error 101 — Why It Happens and How to Respond

Error 101 means the inverter's slave processor has stopped receiving data from the master…

Read diagnosis →
Growatt Inverter Error 102 — Causes and Safe Fixes
Warning

Growatt Inverter Error 102 — Causes and Safe Fixes

Error 102 means your Growatt's two internal processors recorded measurements that don't match —…

Read diagnosis →
Growatt Inverter Error 116 — What It Means & What to Check
Warning

Growatt Inverter Error 116 — What It Means & What to Check

Error 116 means the inverter failed while reading from or writing to its EEPROM…

Read diagnosis →
Growatt Inverter Error 117 — What to Do Next
Warning

Growatt Inverter Error 117 — What to Do Next

Error 117 means the inverter's self-test found a fault in its relay circuit —…

Read diagnosis →
Growatt Inverter Error 119 — Is It Dangerous? What to Do Immediately
Critical

Growatt Inverter Error 119 — Is It Dangerous? What to Do Immediately

Error 119 means the inverter's self-test found a possible fault in its internal GFCI…

Read diagnosis →
Growatt Inverter Error 121 — Practical Steps to Fix It Safely
Warning

Growatt Inverter Error 121 — Practical Steps to Fix It Safely

Error 121 means the inverter's master processor has stopped receiving data from the slave…

Read diagnosis →
Growatt Inverter Error 122 — Causes and Safe Fixes
Warning

Growatt Inverter Error 122 — Causes and Safe Fixes

Error 122 means the inverter's DC bus voltage left its permitted range — often…

Read diagnosis →
Growatt Inverter Error 19 Battery Disconnected and How to Fix It
Warning

Growatt Inverter Error 19 Battery Disconnected and How to Fix It

Error 19 on Growatt SPF-series off-grid and hybrid inverters means the battery is disconnected…

Read diagnosis →
Growatt Inverter Error 411 — When DSP and M3 Boards Stop Talking
Critical

Growatt Inverter Error 411 — When DSP and M3 Boards Stop Talking

Error 411 (“DSP communicates with M3 abnormal”) means the two internal processors in your…

Read diagnosis →
Growatt Inverter Error 58 — Is Low Output Voltage Dangerous?
Warning

Growatt Inverter Error 58 — Is Low Output Voltage Dangerous?

Error 58 on a Growatt SPF off-grid inverter means the AC output voltage has…

Read diagnosis →
Growatt Inverter No AC Connection — Grid Failure or a Tripped Breaker?
Warning

Growatt Inverter No AC Connection — Grid Failure or a Tripped Breaker?

No AC Connection means your Growatt inverter cannot detect the utility grid, so it…

Read diagnosis →
Growatt PV Isolation Low — What It Means and When to Call an Electrician
Critical

Growatt PV Isolation Low — What It Means and When to Call an Electrician

PV Isolation Low means the insulation resistance between your panels and earth has fallen…

Read diagnosis →
Growatt PV Voltage High — Urgent Causes and What to Do Now
Critical

Growatt PV Voltage High — Urgent Causes and What to Do Now

PV Voltage High means your panels are delivering more DC voltage than the inverter's…

Read diagnosis →
Growatt Residual I High — Is It Dangerous? What to Do Immediately
Critical

Growatt Residual I High — Is It Dangerous? What to Do Immediately

Residual I High means the inverter detected leakage current to earth above the safe…

Read diagnosis →

Huawei

12 codes
Huawei Inverter AFCI 3003 — When the Arc-Fault Alarm Trips
Critical

Huawei Inverter AFCI 3003 — When the Arc-Fault Alarm Trips

Your Huawei SUN2000 has detected an electric arc somewhere in the DC wiring between…

Read diagnosis →
Huawei Inverter Alarm 2034 — Grid Overvoltage and HVRT Explained
Warning

Huawei Inverter Alarm 2034 — Grid Overvoltage and HVRT Explained

Alarm 2034 means the grid voltage rose above the upper threshold — or stayed…

Read diagnosis →
Huawei Inverter Alarm 2035 — What Causes Unbalanced Grid Voltage?
Warning

Huawei Inverter Alarm 2035 — What Causes Unbalanced Grid Voltage?

Alarm 2035 means the difference between your three grid phase voltages has exceeded the…

Read diagnosis →
Huawei Inverter Alarm 2039 — Why Output Overcurrent Trips
Warning

Huawei Inverter Alarm 2039 — Why Output Overcurrent Trips

Alarm 2039 means the inverter's transient output current exceeded its protection threshold — typically…

Read diagnosis →
Huawei Inverter Alarm 2051 — Abnormal Residual Current Explained
Critical

Huawei Inverter Alarm 2051 — Abnormal Residual Current Explained

Alarm 2051 means your Huawei SUN2000 detected abnormal residual current — small amounts of…

Read diagnosis →
Huawei Inverter Alarm 2061 — Why Your Grounding Alarm Tripped
Critical

Huawei Inverter Alarm 2061 — Why Your Grounding Alarm Tripped

Alarm 2061 means your Huawei SUN2000 found a problem with its grounding — typically…

Read diagnosis →
Huawei Inverter Alarm 2062 — Is Low Insulation Resistance Dangerous?
Critical

Huawei Inverter Alarm 2062 — Is Low Insulation Resistance Dangerous?

Alarm 2062 means the insulation resistance between your PV array and ground has dropped…

Read diagnosis →
Huawei Inverter Alarm 2063 — Overtemperature and How to Respond
Warning

Huawei Inverter Alarm 2063 — Overtemperature and How to Respond

Alarm 2063 means the inverter cabinet has gotten too hot. Huawei lists three possible…

Read diagnosis →
Huawei Inverter Alarm 2068 — Battery Abnormal and How to Clear It
Info

Huawei Inverter Alarm 2068 — Battery Abnormal and How to Clear It

Alarm 2068 on your Huawei SUN2000 means there is a problem with the connected…

Read diagnosis →
Huawei Inverter Alarm 2069 — Battery Reverse Connection Explained
Critical

Huawei Inverter Alarm 2069 — Battery Reverse Connection Explained

Alarm 2069 on a Huawei SUN2000 means the inverter has detected that the battery…

Read diagnosis →
Huawei Inverter Alarm 2070 — Active Islanding Detection Explained
Warning

Huawei Inverter Alarm 2070 — Active Islanding Detection Explained

Alarm 2070 is Huawei's “Active Islanding” alarm — a Major-severity alarm meaning your SUN2000…

Read diagnosis →
Huawei Inverter Alarms 2036 and 2037 When Grid Frequency Trips
Warning

Huawei Inverter Alarms 2036 and 2037 When Grid Frequency Trips

Huawei alarm 2036 (grid overfrequency) and 2037 (grid underfrequency) mean the actual grid frequency…

Read diagnosis →

SAJ

1 codes

SMA

11 codes
SMA Inverter Arc Fault — The Tap-Twice Reset Explained
Critical

SMA Inverter Arc Fault — The Tap-Twice Reset Explained

When your SMA Sunny Boy detects an electric arc in the DC wiring, it…

Read diagnosis →
SMA Inverter Code 1302 — When the Grid Voltage Never Arrives
Warning

SMA Inverter Code 1302 — When the Grid Voltage Never Arrives

Event 1302 means your SMA inverter can't detect any grid voltage at all —…

Read diagnosis →
SMA Inverter Event 101/102/103 — Grid Fault and What It Means for You
Warning

SMA Inverter Event 101/102/103 — Grid Fault and What It Means for You

Events 101, 102, and 103 on your SMA inverter all mean the same thing:…

Read diagnosis →
SMA Inverter Event 3501/3503 — Ground Fault Found, What to Do Next
Critical

SMA Inverter Event 3501/3503 — Ground Fault Found, What to Do Next

Events 3501 and 3503 mean your SMA inverter has detected a ground fault in…

Read diagnosis →
SMA Inverter Event 401 — Why the Inverter Left the Grid
Warning

SMA Inverter Event 401 — Why the Inverter Left the Grid

Event 401 is SMA's 'Grid incident' message: your inverter disconnected from the utility grid…

Read diagnosis →
SMA Inverter Event 4301 — When Your AFCI Detects an Electric Arc
Critical

SMA Inverter Event 4301 — When Your AFCI Detects an Electric Arc

Event 4301 means your SMA inverter's arc fault circuit interrupter (AFCI) detected an electric…

Read diagnosis →
SMA Inverter Event 801 — Stuck Waiting for Grid Voltage
Warning

SMA Inverter Event 801 — Stuck Waiting for Grid Voltage

Event 801 — “Waiting for grid voltage” — means your SMA Sunny Boy cannot…

Read diagnosis →
SMA Inverter Event 8206 — Electric Arc Detected and What to Do Next
Critical

SMA Inverter Event 8206 — Electric Arc Detected and What to Do Next

Event 8206 means your SMA inverter's arc-fault protection detected an electric arc in the…

Read diagnosis →
SMA Inverter Events 202, 203 and 205 — Grid Gone or Grid Too Low?
Warning

SMA Inverter Events 202, 203 and 205 — Grid Gone or Grid Too Low?

Events 202, 203, and 205 all share one message — 'grid incident': the utility…

Read diagnosis →
SMA Inverter Fac-Bfr or Fac-Srr — What the Grid Frequency Error Means
Warning

SMA Inverter Fac-Bfr or Fac-Srr — What the Grid Frequency Error Means

Fac-Bfr or Fac-Srr means the AC grid frequency is outside the allowable range. Your…

Read diagnosis →
SMA Inverter K1 Open Error — Does the Inverter Need Replacing?
Warning

SMA Inverter K1 Open Error — Does the Inverter Need Replacing?

The 'K1 Open' message means your SMA inverter's self-test found a problem with its…

Read diagnosis →

Sol-Ark

1 codes

SolarEdge

18 codes
SolarEdge Inverter 18X37 V-Line Max — Why Your Inverter Tripped
Warning

SolarEdge Inverter 18X37 V-Line Max — Why Your Inverter Tripped

Error 18X37 (“V-Line Max”) means your single-phase SolarEdge inverter measured AC line voltage above…

Read diagnosis →
SolarEdge Inverter 18XA6 Hardware Fault — What It Means for You
Warning

SolarEdge Inverter 18XA6 Hardware Fault — What It Means for You

Error 18xA6 is an internal hardware fault on single-phase SolarEdge inverters — on the…

Read diagnosis →
SolarEdge Inverter 2X19 Isolation Fault — Meaning and Safe Next Steps
Critical

SolarEdge Inverter 2X19 Isolation Fault — Meaning and Safe Next Steps

Error 2X19 means your SolarEdge single-phase inverter has detected an isolation fault — the…

Read diagnosis →
SolarEdge Inverter 64 — What This Grid Fault Code Means
Warning

SolarEdge Inverter 64 — What This Grid Fault Code Means

Error 64 on a SolarEdge inverter is a grid-protection shutdown, and its exact meaning…

Read diagnosis →
SolarEdge Inverter 8X19–8X1B AC Voltage Too High on Lines 1–3
Warning

SolarEdge Inverter 8X19–8X1B AC Voltage Too High on Lines 1–3

SolarEdge codes 8X19, 8X1A, and 8X1B mean "AC Voltage Too High" on line 1,…

Read diagnosis →
SolarEdge Inverter Error 18XA6 — Practical Steps to Fix It Safely
Warning

SolarEdge Inverter Error 18XA6 — Practical Steps to Fix It Safely

Your inverter's built-in self-check found an internal hardware fault, so it has stopped producing…

Read diagnosis →
SolarEdge Inverter Error 2X13 — Practical Steps to Fix It Safely
Warning

SolarEdge Inverter Error 2X13 — Practical Steps to Fix It Safely

SW Error is an internal software fault in your SolarEdge inverter — it appears…

Read diagnosis →
SolarEdge Inverter Error 33 — What AC Voltage Too High Means
Warning

SolarEdge Inverter Error 33 — What AC Voltage Too High Means

Error 33 on a single-phase SolarEdge inverter means AC voltage too high: the grid…

Read diagnosis →
SolarEdge Inverter Error 36 — DC Injection Fault Explained
Warning

SolarEdge Inverter Error 36 — DC Injection Fault Explained

Error 36 on a SolarEdge inverter means DC Injection: the inverter detected direct current…

Read diagnosis →
SolarEdge Inverter Error 8X10 — What It Means & What to Check
Warning

SolarEdge Inverter Error 8X10 — What It Means & What to Check

The inverter's internal processor lost contact with its own sub-components, so it stopped producing…

Read diagnosis →
SolarEdge Inverter Error 8X19 — Causes and Safe Fixes
Warning

SolarEdge Inverter Error 8X19 — Causes and Safe Fixes

The grid voltage on the indicated line rose above your country's permitted limit, so…

Read diagnosis →
SolarEdge Inverter Error 8X1C — Why It Happens and How to Respond
Warning

SolarEdge Inverter Error 8X1C — Why It Happens and How to Respond

The grid voltage on the indicated line dropped below the permitted minimum, so your…

Read diagnosis →
SolarEdge Inverter Error 8X2B — Is It Dangerous? What to Do Immediately
Critical

SolarEdge Inverter Error 8X2B — Is It Dangerous? What to Do Immediately

Your inverter's residual current device measured leakage current from the DC side to earth…

Read diagnosis →
SolarEdge Inverter Error 8X52 — Causes and Safe Fixes
Warning

SolarEdge Inverter Error 8X52 — Causes and Safe Fixes

Unbalanced DC Voltage (code 8x52) means the inverter detected abnormal voltage imbalance on the…

Read diagnosis →
SolarEdge Inverter Error 8X58 — When to Call an Electrician
Critical

SolarEdge Inverter Error 8X58 — When to Call an Electrician

The insulation resistance between your PV array and earth dropped below the safe limit…

Read diagnosis →
SolarEdge Inverter Fan Failure — Why the Fan Stops and What to Do
Warning

SolarEdge Inverter Fan Failure — Why the Fan Stops and What to Do

One of your inverter's cooling fans has stopped working. This is a warning rather…

Read diagnosis →
SolarEdge Inverter Meter Communication Fault — 3X6E Guide
Warning

SolarEdge Inverter Meter Communication Fault — 3X6E Guide

The meter communication fault — shown as Error 3x6E on newer firmware and Error…

Read diagnosis →
SolarEdge Inverter Temperature Too High — Why It Overheats
Warning

SolarEdge Inverter Temperature Too High — Why It Overheats

Your inverter ran hotter than its safe operating limit and protected itself — it…

Read diagnosis →

Solis

21 codes
Solis Inverter AFCI Check Fault — Why the Self-Test Failed
Warning

Solis Inverter AFCI Check Fault — Why the Self-Test Failed

AFCI Check FAULT means your Solis inverter’s arc-fault detection module failed its startup self-test.…

Read diagnosis →
Solis Inverter ARC-FAULT Error — Is It Dangerous? What to Do Immediately
Critical

Solis Inverter ARC-FAULT Error — Is It Dangerous? What to Do Immediately

An electric arc has been detected in the DC wiring by your Solis inverter's…

Read diagnosis →
Solis Inverter CAN Fail Alarm — Restoring Lost Battery Communication
Warning

Solis Inverter CAN Fail Alarm — Restoring Lost Battery Communication

“CAN Fail” on your Solis hybrid inverter means the CAN-bus communication link between the…

Read diagnosis →
Solis Inverter DCinj-Fault — High DC Injection Explained
Warning

Solis Inverter DCinj-Fault — High DC Injection Explained

DCinj-FAULT means your Solis inverter measured too much DC current leaking into its AC…

Read diagnosis →
Solis Inverter G-IMP Error — A Homeowner’s Troubleshooting Guide
Warning

Solis Inverter G-IMP Error — A Homeowner’s Troubleshooting Guide

The grid connection looks too “soft” — high impedance — for your Solis inverter…

Read diagnosis →
Solis Inverter GRID-INTF Error — What It Means & What to Check
Warning

Solis Inverter GRID-INTF Error — What It Means & What to Check

Your Solis inverter detected interference on the grid connection and disconnected as a precaution.…

Read diagnosis →
Solis Inverter Ground-Fault — What the 1033H Alarm Means for You
Critical

Solis Inverter Ground-Fault — What the 1033H Alarm Means for You

When your Solis shows a GROUND-FAULT alarm (code 1033H), it has detected current leaking…

Read diagnosis →
Solis Inverter GROUND-FAULT Error — When to Call an Electrician
Critical

Solis Inverter GROUND-FAULT Error — When to Call an Electrician

Your Solis inverter found a ground fault — part of the PV system is…

Read diagnosis →
Solis Inverter IGBT-OV-I Error — Causes and Safe Steps
Warning

Solis Inverter IGBT-OV-I Error — Causes and Safe Steps

IGBT-OV-I means your Solis inverter detected overcurrent in its IGBTs — the power transistors…

Read diagnosis →
Solis Inverter ILEAK-FAULT Error — Is It Dangerous?
Critical

Solis Inverter ILEAK-FAULT Error — Is It Dangerous?

Your Solis inverter measured excessive leakage current on the grid (AC) side and shut…

Read diagnosis →
Solis Inverter ILeak-Pro and ILeak-Fault — Leakage Current Alarms
Critical

Solis Inverter ILeak-Pro and ILeak-Fault — Leakage Current Alarms

Solis inverters raise two related leakage-current alarms. ILeak-PRO 01–04 means the leakage-current protection has…

Read diagnosis →
Solis Inverter ILEAK-PRO Error — Urgent Causes and What to Do Now
Critical

Solis Inverter ILEAK-PRO Error — Urgent Causes and What to Do Now

Your Solis inverter detected leakage current — electricity escaping where it should not —…

Read diagnosis →
Solis Inverter NO-Battery — Battery Not Detected, What to Do
Warning

Solis Inverter NO-Battery — Battery Not Detected, What to Do

NO-Battery means your Solis hybrid inverter cannot detect a battery. On a hybrid system…

Read diagnosis →
Solis Inverter NO-GRID Error — Why It Happens and How to Respond
Warning

Solis Inverter NO-GRID Error — Why It Happens and How to Respond

No grid voltage is reaching your Solis inverter, so it has shut down its…

Read diagnosis →
Solis Inverter OV-BUS Error — Why It Happens and How to Respond
Warning

Solis Inverter OV-BUS Error — Why It Happens and How to Respond

Your Solis inverter's internal DC bus voltage went too high (OV-BUS) or too low…

Read diagnosis →
Solis Inverter OV-DC Error — What It Means & What to Check
Warning

Solis Inverter OV-DC Error — What It Means & What to Check

Your panel strings are producing more DC voltage than your Solis inverter can accept.…

Read diagnosis →
Solis Inverter OV-G-F Error — Causes and Safe Fixes
Warning

Solis Inverter OV-G-F Error — Causes and Safe Fixes

The grid frequency rose above your Solis inverter's limit, so it disconnected to stay…

Read diagnosis →
Solis Inverter OV-G-V Error — A Homeowner’s Troubleshooting Guide
Warning

Solis Inverter OV-G-V Error — A Homeowner’s Troubleshooting Guide

Your Solis inverter measured grid voltage above its safe limit and stopped feeding power…

Read diagnosis →
Solis Inverter OV-TEM Error — What to Do Next
Warning

Solis Inverter OV-TEM Error — What to Do Next

Your Solis inverter is overheating and has cut output or shut down to protect…

Read diagnosis →
Solis Inverter UN-G-F Error — Grid Frequency Too Low
Warning

Solis Inverter UN-G-F Error — Grid Frequency Too Low

UN-G-F means the utility grid’s frequency dropped below your inverter’s protection limit, so the…

Read diagnosis →
Solis Inverter UN-G-V Error — Practical Steps to Fix It Safely
Warning

Solis Inverter UN-G-V Error — Practical Steps to Fix It Safely

Grid voltage fell below your Solis inverter's safe limit, so it disconnected. This is…

Read diagnosis →

Sungrow

11 codes
Sungrow Inverter Code 002 — What Does It Mean? A Plain-English Guide
Warning

Sungrow Inverter Code 002 — What Does It Mean? A Plain-English Guide

Sungrow fault code 002 means grid overvoltage — the voltage from your electricity network…

Read diagnosis →
Sungrow Inverter Code 003 — Why Transient Overvoltage Stops Feed-In
Warning

Sungrow Inverter Code 003 — Why Transient Overvoltage Stops Feed-In

Code 003 means your Sungrow inverter detected a brief spike in grid voltage above…

Read diagnosis →
Sungrow Inverter Code 010 — Islanding Explained for Homeowners
Warning

Sungrow Inverter Code 010 — Islanding Explained for Homeowners

Sungrow fault code 010 means “Islanding” — the inverter has detected that grid power…

Read diagnosis →
Sungrow Inverter Code 036 — Why Your Radiator Is Overheating
Warning

Sungrow Inverter Code 036 — Why Your Radiator Is Overheating

Code 036 means the inverter's power module — the IGBT assembly bolted to the…

Read diagnosis →
Sungrow Inverter Code 070 — Is a Defective Fan Stopping Output?
Warning

Sungrow Inverter Code 070 — Is a Defective Fan Stopping Output?

Code 070 means one or more of the inverter's cooling fans are defective —…

Read diagnosis →
Sungrow Inverter Code 088 — What the Arc Fault Warning Means
Critical

Sungrow Inverter Code 088 — What the Arc Fault Warning Means

Code 088 is Sungrow's “Arcing warning” — the inverter's arc-fault (AFCI) protection has detected…

Read diagnosis →
Sungrow Inverter Code 100 — What the Hardware Overcurrent Fault Means
Warning

Sungrow Inverter Code 100 — What the Hardware Overcurrent Fault Means

Code 100 is an inverter overcurrent hardware fault — the current inside your Sungrow…

Read diagnosis →
Sungrow Inverter Code 202 — PV Hardware Overcurrent Fault
Warning

Sungrow Inverter Code 202 — PV Hardware Overcurrent Fault

Sungrow code 202 means "PV hardware overcurrent fault": the current coming in from your…

Read diagnosis →
Sungrow Inverter Codes 004 and 005 — Grid Undervoltage Explained
Warning

Sungrow Inverter Codes 004 and 005 — Grid Undervoltage Explained

Codes 004 and 005 both mean grid undervoltage — the AC voltage from the…

Read diagnosis →
Sungrow Inverter Error Code 014 — 10-Minute Grid Overvoltage Explained
Warning

Sungrow Inverter Error Code 014 — 10-Minute Grid Overvoltage Explained

Code 014 means the 10-minute average voltage from your electricity grid stayed above the…

Read diagnosis →
Sungrow Inverter Error Code 038 — Is Your Grid-Side Relay Faulty?
Warning

Sungrow Inverter Error Code 038 — Is Your Grid-Side Relay Faulty?

Code 038 means your Sungrow inverter's self-check found a problem with the relay on…

Read diagnosis →