Fronius Inverter STATE 567 — Normal Behavior or a Real Problem?
STATE 567 is informational: Grid Voltage Dependent Power Reduction — volt-watt mode — is active. The inverter is deliberately reducing its output because grid voltage is high, and it recovers automatically as voltage falls.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
STATE 567 tells you that Grid Voltage Dependent Power Reduction — GVDPR, usually called volt-watt mode — has activated. When grid voltage climbs too high (above about 250V AC), the inverter deliberately trims its power output. Less power exported means less voltage rise on the local network, so the inverter is actively helping to bring the grid back down. This is normal, standards-compliant behavior — the grid codes in many countries require it.
What you will notice: the inverter keeps running, just at reduced power, and a message appears on the display asking to be acknowledged — press Enter to clear it. In Solar.web you may see output dipping on sunny middays even though nothing is shaded and nothing is broken. That dip is volt-watt mode doing its job, and output returns to normal by itself as grid voltage falls.
The related code is STATE 102, and the difference matters: 567 is the inverter managing high voltage by producing less, while 102 is the inverter disconnecting because voltage passed the hard limit. Seeing 567 occasionally on hot, sunny middays is unremarkable. Seeing it constantly, with a real dent in your generation, is the point to involve your installer.
Common causes
- Elevated grid voltage during high solar export. Clear middays, when every rooftop system in the area is exporting, are the classic trigger.
- Local network voltage running near the upper limit. If your street already sits high, even moderate export pushes it past the volt-watt threshold.
- Voltage rise from your own system exporting. Exporting power raises the voltage at your connection — the very effect volt-watt mode is designed to counter.
- Network conditions in your area. Transformer tap settings and local network impedance shape how high voltage climbs under export.
- Strong solar output combined with low daytime demand. When the neighborhood generates far more than it consumes, the excess has nowhere to go but up — in voltage.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 4 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Contact your solar installer if 567 keeps recurring and is significantly reducing your generation. They can review the volt-watt response settings against your country's grid code and, if the pattern points at the network rather than your system, help arrange a voltage assessment with your network operator.
One thing that is not on the table: disabling volt-watt mode. It is required by grid standards, and switching it off would breach your grid connection terms. The legitimate fixes — settings review, network assessment — all run through professionals.
Frequently asked questions
Is STATE 567 a fault?
No. It is the inverter working exactly as designed — reducing output to manage high grid voltage, as grid standards require. It clears automatically as voltage falls.
Why is my output lower when 567 shows?
That is the entire point of volt-watt mode: less exported power means less voltage rise on the grid. Output returns to normal by itself as grid voltage drops.
Can I turn off volt-watt mode to get my power back?
No — it is required by grid standards and must stay enabled. If it is hurting your generation, your installer and network operator are the right people to talk to, not the settings menu.
How much generation am I actually losing?
Only during the high-voltage periods, and usually only a fraction of output. But if 567 appears daily and the dips are deep, the monthly total adds up — log the pattern and show it to your installer.
Does acknowledging the message on the display stop it?
No — pressing Enter only clears the message from the screen. Volt-watt mode itself runs automatically and independently; it will keep activating whenever grid voltage climbs.
Sources: meaning and troubleshooting verified against the manufacturer's documentation — Fronius Operating Instructions (Symo/Primo) — 'Status codes and remedy' / 'STATE CODES' tables (Fronius docs 42,0410,0192 & 42,0410,1909 series)