Info What does this mean?
A status message, not a fault. It usually clears on its own and needs no action from you.
Fronius Inverter STATE 102 — What Does It Mean? A Plain-English Guide
STATE 102 means the AC grid voltage is too high. The inverter has disconnected for safety and will resume automatically once voltage is back in range. The cause is usually the grid — especially midday solar export — not a fault in your inverter.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
STATE 102 is a Class 1 grid status code: the AC voltage at the inverter rose above the permitted limit — it must stay within +10%/−12% of nominal — so the inverter disconnected from the grid. Like all Class 1 codes, the cause is typically the grid rather than a device fault. The inverter tests conditions continuously and resumes feeding power automatically after a stable observation period.
This code loves sunny middays, and there is a clear reason. When every rooftop solar system in the neighborhood exports at once, all that power flowing back through the local network pushes the voltage up. Your own system contributes: exporting power raises the voltage at your connection point, a phenomenon installers call voltage rise. So the sunniest, most productive part of the day is exactly when 102 is most likely to appear.
A midday pattern is the signature of a grid-voltage issue. The property-side suspect is different: a loose neutral connection can also produce high voltage readings, but that needs a professional check — it is not something to investigate yourself. If 102 appears at odd hours with no sun, or alongside other electrical oddities in the house, skip the waiting and call your installer.
Common causes
- High grid voltage during peak solar export. On clear middays, neighborhood-wide exporting lifts local voltage toward — and past — the inverter's limit.
- Voltage rise from your own system. Exporting power inherently raises the voltage at your connection point; systems on long cable runs feel this most.
- A network transformer tap set high. If the local transformer is tapped toward the top of its range, the whole street starts the day near the limit and solar export tips it over.
- A loose neutral connection. This is the property-side cause: a poor neutral raises the voltage the inverter measures, and it needs an electrician to find and fix.
- Generally high supply voltage in your area. Some streets simply run hot; combined with midday export, the inverter's upper limit gets hit regularly.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 5 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
If 102 keeps recurring, call your system installer. They will look at the timing pattern you have recorded and decide whether this is a network problem — in which case your network operator needs to assess local voltage, possibly adjusting the transformer tap — or something closer to home, like the inverter's volt-watt response settings or a loose neutral.
Never change grid-code settings yourself; incorrect settings can breach your grid connection agreement and create safety issues. A professional review keeps the system compliant while recovering the lost generation.
Frequently asked questions
Why does 102 always happen on sunny days?
When lots of rooftop solar exports at once, local grid voltage rises. Your inverter disconnects to stay within its legal limits, then reconnects when voltage settles — usually as the export peak passes.
Will this damage my inverter?
No. Disconnecting is the protection working exactly as designed. The inverter is built for this; it is the repeated lost generation, not hardware damage, that makes frequent 102s worth addressing.
Can anything be done about frequent 102 codes?
Yes, but only by professionals. Your installer can review the inverter's volt-watt settings and your network operator can assess local voltage. Never change grid settings yourself.
Should I worry about my home appliances too?
Mildly — sustained high voltage is harder on appliances than on your inverter. If 102 is frequent, mention it to your installer; a network operator assessment protects the whole street, not just your solar.
Is 102 the same as 567?
Related but different. 567 is the inverter reducing its output proactively to manage high voltage; 102 is the inverter disconnecting because voltage exceeded the hard limit. Both are responses to high grid voltage.
Sources: meaning and troubleshooting verified against the manufacturer's documentation — Fronius Operating Instructions (Symo/Primo) — 'Status codes and remedy' / 'STATE CODES' tables (Fronius docs 42,0410,0192 & 42,0410,1909 series)