Fronius Inverter STATE 103 — Should You Worry?

Fronius Inverter STATE 103 — Should You Worry?

STATE 103 means the AC grid voltage is too low. The inverter has disconnected from the grid as required by grid standards and will automatically resume once voltage returns to the permitted range.

What should I do first?

Two quick questions — we'll point you to the right starting point.

Is this code still showing on your inverter's display?

What this code means

STATE 103 is a Class 1 grid status code: the inverter measured AC voltage below the permitted limit and disconnected from the grid, exactly as grid standards require. It is not a device fault. The inverter keeps testing conditions in the background and resumes feeding power automatically once voltage has been back in range for the required observation period.

Low grid voltage — the brownout — usually comes from the network, not your home. It happens when local demand strains the supply: hot evenings with every air conditioner running, or a grid operating near its limits. Long cable runs to your property can make it worse, since voltage drops along the length of the cable. One strong clue it is the grid: the code appears at the same time of day, day after day, tracking peak demand rather than anything your system does.

The companion code is STATE 102, the mirror image — AC voltage too high. Both are Class 1 statuses with the same automatic recovery, and both are overwhelmingly likely to be grid conditions rather than inverter faults. The line where 103 stops being “just the grid” is frequency: an occasional dip is normal network behavior, but a 103 that appears daily or lasts for long stretches deserves professional attention.

Common causes

  • Temporary low voltage on the local grid — the classic brownout. When the network sags, the inverter disconnects to stay within its permitted operating range.
  • High local demand straining the network. Early evenings, when households all draw power at once, are the most common window for undervoltage events.
  • Long cable runs causing voltage drop. The farther your property is from the transformer, the more voltage is lost along the cable — making dips deeper at your inverter.
  • A loose AC connection. Less common, but a poor terminal at the inverter or switchboard can depress the voltage the inverter sees — worth considering if 103 appears at odd hours.
  • A supply problem affecting your street or area. A struggling local transformer or degraded network cabling can hold voltage down for extended periods.

Safe steps to try

Work top to bottom, ticking off each step as you complete it. 0 of 5 done.

Is your inverter still under warranty?

Before paying for a repair, check — your installer may fix this free.

Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.

When to call an electrician

Contact your system installer if 103 keeps recurring — daily appearances, long durations, or a clear impact on your generation. Persistent undervoltage may need your network operator to investigate the local supply, or an electrician to check your connection and the AC wiring to the inverter.

What the installer will want first is your notes: when it happens, how long it lasts, whether the neighbors see it too. That pattern is what separates a network problem (the operator's responsibility) from a connection problem (yours). Either way, grid voltage is not something a homeowner can or should try to correct.

Frequently asked questions

Is STATE 103 dangerous?

No. It is the inverter doing its job — disconnecting when grid voltage leaves its permitted range, then reconnecting automatically. The protection working is the opposite of a problem.

Why does it happen at the same time every day?

Grid voltage dips during peak demand, often in the early evening. If the timing is that regular, it is almost certainly the network — and if it is frequent enough to hurt your generation, your installer can advise on next steps.

What is the difference between 103 and 102?

103 is AC voltage too low; 102 is AC voltage too high. Both are Class 1 grid statuses, both disconnect the inverter, and both recover automatically once voltage returns to range.

Am I losing much solar production to this?

Only during the dips themselves, which are usually brief. But a 103 that appears daily for long stretches adds up — track how often it happens, and call your installer if the lost generation becomes noticeable.