Fronius Inverter STATE 106 — Should You Worry?
STATE 106 means the grid frequency dropped too low, so your inverter briefly disconnected for safety. It reconnects automatically once the grid stabilizes — there is no fault in your equipment.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
Your inverter constantly watches the AC grid it feeds into — including grid frequency, which should hold steady at its nominal value. STATE 106 means the frequency fell below the permitted range, so the inverter disconnected from the grid, exactly as grid standards require. Grid codes everywhere demand this behavior — your inverter isn’t being overcautious, it’s obeying the rules it was certified to.
Fronius lists this as a Class 1 status: typically temporary, and caused by the grid rather than your inverter. The manual states explicitly that no device fault has occurred. The disturbance was out on the utility network; your inverter simply stepped away until conditions returned to normal. It cannot feed power into a grid whose frequency is out of bounds, so stepping away is the only compliant option.
A frequency dip doesn’t always mean an outage — your lights may stay on throughout. Either way, there’s nothing for you to do. The inverter watches the grid for the observation period your country’s grid standard demands, then resumes feeding power automatically once the frequency is back in range. No reset, and the status leaves the display on its own.
Common causes
- A grid frequency dip — a utility-side event where the network’s frequency sags briefly. The most common cause, and entirely outside your home.
- A large load switching nearby — heavy equipment starting up can drag local frequency down for a moment.
- Utility work or a network fault — line maintenance or a distant fault can ripple through as a brief frequency disturbance.
- A storm hitting the network — high winds or lightning strikes on utility lines cause the momentary dips that trigger this status.
- Wrong country or grid setup — rare, and an installer-only setting. Suspect it only if STATE 106 keeps recurring under otherwise normal conditions.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 4 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
If STATE 106 keeps coming back, call your installer — that’s the manual’s stated remedy for recurring cases. A one-off that clears itself needs nothing. Keep your notes anyway — dated events let the technician match your outages against the utility’s recorded disturbances.
Bring the times and durations you noted. The technician will read the inverter’s event history, confirm the country and grid settings match your region, and — if your local network is genuinely unstable — take it up with the utility. Grid settings are installer-only parameters tied to your country’s grid code, so this is one problem you can’t solve from the app.
Frequently asked questions
Is STATE 106 a fault with my inverter?
No. The manual states explicitly that no device fault has occurred — the cause is in the grid. Your inverter protected itself and will resume on its own.
How long before it reconnects?
Once the grid stays stable for the full observation period your country’s grid standard requires — usually a matter of minutes rather than hours after the dip ends.
What should I actually do while I wait?
Nothing the inverter needs — it’s watching the grid. Just note the time and duration. If your lights stayed on, you’ve already confirmed it was a frequency dip rather than an outage.
Should I reset the inverter?
No — resetting interrupts the inverter’s grid observation period and can delay reconnection. Just wait it out, and only call your installer if the code keeps returning.
It’s happened three times this week — is that normal?
That’s the pattern that matters. Repeated 106s point to an unstable local grid or a wrong country/grid setup on the inverter. Give your installer the dates and times so they can check both.