Info What does this mean?

A status message, not a fault. It usually clears on its own and needs no action from you.

Fronius Inverter STATE 107 — What It Means and When to Worry

Fronius Inverter STATE 107 — What It Means and When to Worry

STATE 107 means the inverter cannot detect the AC grid — it is waiting for acceptable grid conditions before it reconnects and resumes feeding power. The cause is the grid, not your inverter.

What should I do first?

Two quick questions — we'll point you to the right starting point.

Is this code still showing on your inverter's display?

What this code means

STATE 107 is a Class 1 status code, which is Fronius's way of saying the cause lies with the grid, not with your inverter. “No AC grid detected” means exactly that: the inverter looked for the grid and did not find acceptable conditions, so it disconnected and is now watching and waiting. No device fault has occurred, and there is nothing wrong with the inverter itself.

The useful question with 107 is always: is this a grid problem or my problem? A grid problem looks like this — the neighbors are dark too, or you know there is an outage or maintenance work in the area. Your problem looks like this — the house has power, the neighbors are fine, and the inverter still sees no grid. That second pattern points at your own equipment: a tripped AC breaker, a switched-off isolator, or a loose AC connection between the switchboard and the inverter.

Once the grid is back and stable, the inverter reconnects on its own. It does not reconnect the instant power returns — it must observe stable grid conditions for a set period first, as your country's grid code requires. That waiting period is typically a few minutes after the power comes back, and then feed-in resumes with no action from you.

Common causes

  • A grid outage or blackout in your area. Storms, network faults, and planned maintenance all remove the grid the inverter needs — and 107 is the correct response.
  • A tripped AC breaker or a switched-off isolator. If the breaker feeding the inverter has tripped, or someone switched the AC isolator off, the inverter sees no grid even though the street has power.
  • Utility maintenance on the local network. Planned works can take the local grid down for hours; the inverter simply waits it out.
  • A loose AC connection at the inverter or switchboard. Less common, but a poor connection can interrupt the grid supply the inverter monitors — worth suspecting when the house otherwise has power.
  • Storm or accident damage to local lines. A downed line or damaged pole in your area takes the local grid down until repair crews restore it — and the inverter simply waits with everyone else.

Safe steps to try

Work top to bottom, ticking off each step as you complete it. 0 of 5 done.

Is your inverter still under warranty?

Before paying for a repair, check — your installer may fix this free.

Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.

When to call an electrician

Contact your system installer if 107 persists while the rest of your home has normal grid power. That combination — house fine, inverter blind — points at your own equipment rather than the grid, and it needs an electrician's eyes on the AC isolator, the breaker, and the wiring between the switchboard and the inverter.

If the whole street is dark, the right call is your network operator or utility, not your installer — there is nothing they can fix until the grid returns. And if outages are frequent where you live, mention it to your installer anyway; repeated 107s are worth having on the system's record.

Frequently asked questions

Do I need to reset the inverter after a blackout?

No. It reconnects automatically once the grid is stable — just make sure the AC breaker and isolator are switched on. There is nothing to acknowledge or restart.

How long after the power comes back will it start generating?

Typically a few minutes. The inverter must observe stable grid conditions for a set period, required by your country's grid code, before it is allowed to reconnect. Then feed-in resumes on its own.

My lights are on but the inverter shows 107. What is wrong?

Then the grid is fine and the problem is on your side: a tripped solar AC breaker, a switched-off isolator, or a loose AC connection. Check the first two yourself; the third needs your installer.

Is it safe to leave everything switched on during an outage?

Yes. The inverter is designed to sit in this state indefinitely, testing the grid and waiting. Just do not go switching isolators or breakers repeatedly while you wait.

We get 107 every time there is a storm. Is something wrong with my system?

Not necessarily — storms cause grid outages and protection trips, and 107 is the correct response each time. It becomes an installer question only if 107 appears when the grid is clearly fine.

Sources: meaning and troubleshooting verified against the manufacturer's documentation — Fronius Operating Instructions (Symo/Primo) — 'Status codes and remedy' / 'STATE CODES' tables (Fronius docs 42,0410,0192 & 42,0410,1909 series)