Fronius Inverter STATE 306 — Normal Behavior or a Real Problem?
STATE 306 (LOW PV POWER) means there is not enough sunlight for the inverter to feed the grid — it appears every morning and evening and is not a fault. It clears by itself.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
At dawn and dusk your panels make electricity, just not enough of it. When the inverter’s intermediate circuit voltage sinks below the threshold for grid feed, the display shows STATE 306, “LOW PV POWER”. Feed-in pauses and the inverter drops back to its startup phase, waiting for more light.
Fronius is explicit: 306 (LOW PV POWER) and its companion 307 (LOW PV VOLTAGE) appear naturally every morning and evening because sunlight is weak then — “not the result of a fault.” Seeing 306 at the edges of the day is the inverter behaving exactly as designed. In Solar.web you’ll see 306 logged as a status rather than an error — Fronius classifies it as a status code, and the manual treats it the same way.
What separates normal from abnormal is the pattern over several sunny days. Normal: 306 at sunrise, gone by mid-morning, back at sunset. Abnormal: 306 holding through bright midday sun, or appearing at midday day after day. The companion code 307 measures the other half of the same story — voltage rather than power — and the two often appear together in low light; both clear on their own as the sun climbs.
Common causes
- Dawn and dusk — the everyday pattern. Light is simply too weak for feed-in, and the code comes and goes with the sun.
- Heavy cloud or storms — thick cover can drag power below the threshold even at midday; it clears with the sky.
- New shading or dirty panels — a grown tree, a new structure, or a film of dust and pollen cutting what the cells receive.
- The abnormal pattern: 306 holding through bright midday, repeatedly — the manual’s own trigger for calling your installer, since it suggests an underperforming or disconnected string.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 5 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Only when the pattern breaks: 306 recurring in bright daylight is the manual’s cue to call your system installer. Morning and evening appearances need nothing at all.
When you call, bring your log — the times, the weather, how many days it’s run. The technician will compare string performance, hunt for an underperforming or disconnected string, and assess shading or soiling you can’t safely check from the roof. The technician traces the suspect string with string-level measurements and advises the repair from there. There’s no homeowner reset for a genuine low-power condition, and anything on the DC side belongs to qualified personnel.
Frequently asked questions
Is STATE 306 an error?
No — the manual says it appears naturally every morning and evening in weak sunlight, and stresses it is not the result of a fault.
Why does it show up every day?
Your panels can’t make enough power at dawn and dusk for grid feed, so the inverter pauses and waits. It resumes automatically as the light builds.
What does the normal pattern look like?
306 at sunrise, clearing by mid-morning, then back at sunset. If that’s what you see on sunny days, your system is behaving exactly as designed — no action needed.
When should I worry about 306?
When it holds through bright midday sun, especially several days running — that points to a panel or string problem. Log the times and call your installer.
What’s the difference between STATE 306 and 307?
306 means the PV power (watts) is too low for feed-in; 307 means the DC input voltage (volts) is too low. Companion codes — they often appear together in low light.