Fronius Inverter STATE 307 — What It Means and When to Worry
STATE 307 (DC LOW) means the DC voltage from your panels is too low for the inverter to feed power into the grid. It appears routinely at dawn and dusk and clears by itself — it is not a fault.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
On a Fronius inverter, STATE 307 is a status message — not a fault code. Its full description in the Fronius operating instructions is “DC low: DC input voltage too low for feeding energy into the grid.” In plain terms, your solar panels are producing some electricity, but not at a high enough voltage for the inverter to convert it and push it into your home or the grid.
When this happens, the inverter briefly interrupts grid feed-in and returns to its startup phase, where it waits. The moment panel voltage rises enough — as the sun climbs — the inverter automatically resumes normal operation. You do not need to reset anything, and there is nothing to acknowledge or clear.
Fronius explicitly states that STATE 307, alongside STATE 306 (“Power low”), appears routinely in the early morning and evening because sunlight is weak at those times. The manual's wording: these status codes “do not indicate any kind of fault.” So if you see 307 on the inverter display or in Solar.web around sunrise or sunset, the inverter is behaving exactly as designed.
The companion code STATE 306 is closely related but different: 306 means the available PV power is too low, while 307 means the DC input voltage is too low. In practice the two often appear together in low light, and both clear on their own.
Common causes
- Low sunlight at dawn and dusk — the normal, everyday cause. Panel voltage follows sunlight intensity, so it dips below the feed-in threshold every morning and evening.
- Heavy cloud, rain, or storms — thick cloud can cut sunlight enough to trigger 307 even in the middle of the day. It clears when the sky brightens.
- New or grown shading — a tree that has grown taller, a new neighboring structure, or even a tall vehicle parked where it shades part of the array lowers the string voltage.
- Dirty panels — dust, bird droppings, or a film of pollen reduce the light reaching the cells. A visual check from the ground is enough; never climb onto the roof yourself.
- An underperforming or disconnected string — if one of several panel strings stops contributing (damaged panel, loose connection, failing bypass diode), total voltage can sag. Suspect this when 307 appears in strong, unshaded sunlight.
- String design near the voltage limit — if the array was designed with a string voltage close to the inverter's minimum operating voltage, 307 appears more often and earlier in the day. Only your installer can assess and correct this.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 5 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Call your solar installer if STATE 307 appears regularly in strong, unshaded sunlight, if it persists for hours around midday, or if your system's daily energy production has noticeably dropped. Those patterns point to a string or array problem rather than normal low light.
Fronius's own remedy guidance for recurring status codes is to contact a Fronius-trained service technician or your system installer. The technician will measure string voltages, verify the string configuration against the inverter's operating window, and check for shading, soiling, or failing panels. There is no homeowner reset or setting change that fixes a genuine low-voltage condition — and the inverter's DC side must only be handled by qualified personnel.
Frequently asked questions
Should I worry about STATE 307 every morning?
No. It is as routine as sunrise. The inverter waits for enough light, then starts feeding power on its own. Fronius documents this as normal behavior, not a fault.
STATE 307 shows at midday — what now?
That is not normal. Note the time and weather, check for obvious new shading, then call your installer. A string may be underperforming or disconnected, and only a technician should test the DC side.
What is the difference between STATE 306 and 307?
306 means the PV power (watts) is too low for feed-in; 307 means the DC input voltage (volts) is too low. They are companion codes that often appear together in low light, and neither indicates a fault on its own.
Will STATE 307 clear by itself?
Yes. The inverter returns to its startup phase and automatically resumes feeding power once panel voltage recovers. There is nothing to reset or acknowledge.
Am I losing money while 307 is displayed?
Only negligibly. The code appears when there is too little sunlight to generate meaningful power anyway — at dawn, dusk, or under heavy cloud. If it appears during productive hours, the lost generation is real, which is why midday occurrences deserve a call to your installer.
Sources: meaning and troubleshooting verified against the manufacturer's documentation — Fronius Symo / Fronius Eco Operating Instructions — 'Status codes' table (manuals.fronius.com/html/4204101909): 307 = 'DC low — DC input voltage too low for feeding energy into the grid'; behavior: inverter returns to startup phase; 'IMPORTANT: due to low insolation early morning/evening, 306 and 307 are displayed routinely — these status codes do not indicate any kind of fault'; remedy: fault corrected automatically; if recurring, contact system installer / Fronius-trained service technician.