Warning What does this mean?
Your system is down or running degraded, but this is not an immediate safety danger. Work through the safe steps below.
SolarEdge Inverter Error 36 — DC Injection Fault Explained
Error 36 on a SolarEdge inverter means DC Injection: the inverter detected direct current leaking into its AC output and shut down. On newer firmware the same fault shows as 2x24; on three-phase inverters the per-line numbers are 72, 74, and 75 (newer: 8x27 / 8x29 / 8x2A). Grid codes strictly limit DC on the AC side because it can saturate distribution transformers, so the inverter treats any measured DC component as a stop-everything event. SolarEdge's official guidance for this fault is a single line: contact SolarEdge support. There is no homeowner adjustment.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
Everything downstream of your inverter — your home's wiring, the street's transformer, your neighbors' equipment — is built for alternating current. Direct current leaking onto the AC side is not just untidy; a DC component flowing through a distribution transformer pushes its magnetic core toward saturation, which overheats the transformer and distorts power quality for everyone on it. That is why every grid code on the planet sets a hard limit on DC injection, and why inverters are required to watch for it continuously.
Error 36 is the tripwire: the inverter constantly measures its AC output for DC content and disconnects the moment it crosses the threshold. Single-phase inverters show 36 on older firmware or 2x24 on v3.19xx and later; three-phase inverters report per line — 72, 74, 75 (older) or 8x27/8x29/8x2A (newer). The meaning is identical everywhere: DC where only AC should be.
What makes this fault unusual is the thinness of its troubleshooting row. Most rows name a cause and checks; the DC Injection row carries only 'Contact SolarEdge support.' That absence is the message: no external condition to wait out, no setting to correct, no useful homeowner measurement. It is either a transient support clears from diagnostics or an internal power-electronics problem ending in a service case.
In practice the outcomes split cleanly: a one-off event that never returns after a single careful power cycle was likely transient; a 36 that returns or never clears means the inverter keeps measuring real DC, pointing at the power stage and often a warranty replacement.
What is this downtime costing you?
Rough estimate while your system isn't producing. Adjust the numbers to match your setup.
≈ – kWh of lost production per day.
Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.
Common causes
- An internal power-electronics fault in the inverter's output stage. This is the cause most consistent with a persistent or recurring 36: something in the conversion circuitry is genuinely passing a DC component, and only SolarEdge's diagnostics — usually run remotely — can confirm it.
- A transient measurement excursion. Inverters sample their output thousands of times per second, and a sufficiently violent grid event can produce a momentary reading that crosses the DC threshold without any underlying defect. The single power cycle described below is the test for this case.
- A firmware-level measurement issue. Support occasionally resolves DC injection flags with a remote firmware action when their diagnostics show the "injection" was a sensing artifact rather than real DC on the output. This is diagnosed from the inverter's logs, never from anything visible at home.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 4 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Call a professional now — waiting serves nothing here. SolarEdge documents no homeowner remedy, so every day the code stands is lost generation. Support runs manufacturer-level diagnostics, often remotely; if those confirm real DC, the usual outcome is a warranty replacement arranged between installer and SolarEdge. Never let anyone 'adjust' the inverter to clear it — the threshold is a grid-code safety limit, not a setting.
Frequently asked questions
What is the difference between error 36 and 2x24?
They are the same DC Injection fault in different firmware dialects: 36 on older single-phase firmware, 2x24 on newer (72/74/75 and 8x27/8x29/8x2A are the three-phase equivalents). The meaning and the remedy are identical.
Is DC injection dangerous?
To the grid, yes — which is why the inverter disconnects instantly. To you directly, the inverter's shutdown is the protection working. The danger would be in defeating the protection, which is why there is no homeowner reset procedure beyond a single power cycle.
Will it clear on its own like a grid-voltage fault?
No. A grid-voltage fault clears when the grid recovers; a DC injection trip latches until the cause is resolved. If one power cycle does not clear it, it needs SolarEdge support, not patience.
Can my installer fix this on site?
Sometimes the resolution is remote — support's diagnostics and an occasional firmware action. But a genuine, recurring DC component usually ends in a warranty replacement of the inverter, which your installer coordinates with SolarEdge.
Need a professional?
This fault may need professional diagnosis. Contact a qualified solar electrician in your area.
Sources: meaning and troubleshooting verified against the manufacturer's documentation — SolarEdge 'Troubleshooting SolarEdge Systems, Addendum (North America)' — Error Codes table, DC Injection (Line 1/2/3) row (single-phase CPU v3.18xx: 36 → v3.19xx: 2x24; three-phase: 72/74/75 → 8x27/8x29/8x2A; troubleshooting: 'Contact SolarEdge support.'). Note: Knowledge Center direct access was bot-blocked (HTTP 403); verification used verbatim official-document text via indexed mirrors, cross-checked across multiple hosts.