Warning What does this mean?

Your system is down or running degraded, but this is not an immediate safety danger. Work through the safe steps below.

Solis Inverter DSP-B-FAULT — When a Restart Isn’t Enough

Solis Inverter DSP-B-FAULT — When a Restart Isn’t Enough

DSP-B-FAULT means your Solis inverter’s main processor lost communication with its secondary (slave) processor — a “comm. failure between main and slave DSP.” The inverter cannot run safely on one processor, so it stops. Solis’s remedy is a restart or a call to your installer: try the restart once, then call.

What should I do first?

Two quick questions — we'll point you to the right starting point.

Is this code still showing on your inverter's display?

What this code means

DSP stands for digital signal processor — the specialized chips that run your inverter’s control loops, from tracking the maximum power point of your panels to synchronizing with the grid. Larger Solis inverters split this workload between two processors: a main DSP and a slave DSP that must stay in constant communication.

DSP-B-FAULT means that communication link has failed. With the two processors unable to coordinate, the inverter cannot guarantee safe, synchronized operation, so it shuts down rather than run half-blind. This is the correct protective response — an inverter guessing at grid synchronization is worse than an inverter sitting idle. There is no partial-credit mode here: the two processors either agree, or the inverter stands down. That all-or-nothing design is deliberate, because synchronization done wrong can feed dangerous power back into the network — so the inverter chooses silence over uncertainty.

Solis’s troubleshooting table is brief on this one: restart the inverter, or contact the installer. The manual’s startup-troubleshooting notes add that the internal connectors between the main board, the power board, and the DSP should be checked — but those connectors live inside the casing, which makes this an installer-only diagnosis if the restart does not work.

What is this downtime costing you?

Rough estimate while your system isn't producing. Adjust the numbers to match your setup.

–per day
–per week
–per 30 days

≈ – kWh of lost production per day.

Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.

Common causes

  • A transient communication glitch between the two processors — the most common cause, and the one a restart resolves.
  • A loose internal connector on the main board, power board, or DSP link — Solis’s own notes point to these connectors, but checking them means opening the inverter, so this is strictly a technician task.
  • A failing control board — if neither a restart nor reseated connectors restore communication, the processor hardware itself is suspect.

Safe steps to try

Work top to bottom, ticking off each step as you complete it. 0 of 5 done.

Is your inverter still under warranty?

Before paying for a repair, check — your installer may fix this free.

Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.

When to call an electrician

Call your solar installer if DSP-B-FAULT appears a second time. The remaining diagnostic steps — checking the internal board and DSP connectors, testing the control boards — all require opening the inverter and working around energized DC components, which only qualified personnel may do. There is no homeowner setting or external check that restores processor communication; a repeat of this code is by definition an installer visit.

Frequently asked questions

What is a DSP?

A digital signal processor — a chip optimized for the rapid math of power conversion: tracking your panels’ maximum power point, shaping the AC waveform, and staying synchronized with the grid. Your inverter uses two of them sharing the workload, and they must talk to each other constantly to keep the output safe and stable. The ‘B’ in DSP-B-FAULT designates the secondary (slave) processor side of that link — the fault is specifically about communication between the main processor and its backup.

Can I fix DSP-B-FAULT by restarting?

Sometimes — a single communication glitch can clear with the documented restart, and Solis lists restart as the first remedy. But if the code comes back, the cause is hardware: a loose internal connector or a failing board. No amount of restarting fixes hardware.

Am I losing a lot of power while this code is active?

Your system produces nothing while the inverter is down, so every day offline is a day of lost generation. That is the practical cost of this fault — there is no safety hazard to your home, but there is every reason to get the installer scheduled promptly.

Could a firmware update prevent this?

Possibly, if the root cause is a software bug rather than hardware — but firmware updates on an inverter are installer work, and they will not help a genuinely loose connector or failing processor. Let your installer diagnose first and decide whether an update is part of the fix.

Need a professional?

This fault may need professional diagnosis. Contact a qualified solar electrician in your area.

Sources: meaning and troubleshooting verified against the manufacturer's documentation — Solis S6-GC3P(37.5–60)K Installation and Operation Manual, Ver 1.0 (Ginlong Technologies, 2024), Table 8.1 Troubleshooting: DSP-B-FAULT — Comm. failure between main and slave DSP; remedy: restart inverter or contact installer; startup-troubleshooting notes reference checking the connectors on the main board, power board, and DSP link.