Growatt Inverter Error 122 — Causes and Safe Fixes
Error 122 means the inverter's DC bus voltage left its permitted range — often because the solar input is too high or low. The unit shuts down. Note any PV voltage on the display, try one restart, and call your installer if it comes back.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
Between your panels and the grid connection inside the inverter sits the DC bus: a high-voltage internal stage that collects the panels' DC, smooths it, and feeds the conversion circuitry that makes grid-ready AC. It's the heart of the power path, and it operates within strict voltage limits.
Error 122 means the bus voltage has gone out of range. Growatt's troubleshooting guide states it plainly — 'the Bus voltage is out of range' — without naming a single cause, because several things can push it there. The most common is the panel input itself: too much string voltage drives the bus too high, too little leaves it too low. But the bus has its own capacitors and voltage-sensing circuits, so an internal fault can also produce a 122 with perfectly healthy panels.
It's worth distinguishing from the 'PV Voltage High' fault: that one is specifically about the panel input exceeding the inverter's maximum DC rating — a string-design problem. Error 122 is broader — the internal bus, not just the input — and can appear even when the panel voltage looks reasonable. A cold, bright morning is the classic trigger for the high side: panels produce higher voltage when cold, so a string that's fine in summer can push the bus over the limit on a freezing dawn.
What is this downtime costing you?
Rough estimate while your system isn't producing. Adjust the numbers to match your setup.
≈ – kWh of lost production per day.
Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.
Common causes
- Excessive PV string voltage — too many panels in series for the inverter's DC limits drives the bus above range. The classic setup error.
- Cold-weather voltage rise — panel voltage climbs as temperature falls, so a marginally-designed string can trip 122 on freezing bright mornings and behave all summer.
- PV voltage below the operating range — heavy shading, a disconnected string, or severe soiling can starve the bus from below.
- Failing bus capacitors or voltage-sensing circuits — internal components age, and if the sensing drifts, the inverter reads a healthy bus as out of range.
- A transient spike on the DC side — rare, but a sharp event can momentarily throw the bus out of limits and latch the fault.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 4 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Call your installer if Error 122 persists after a restart, recurs on cold mornings, or shows a PV voltage near or above the 'max DC voltage' on the inverter's nameplate or datasheet. The likely fix is a string reconfiguration — typically fewer panels per string — which is strictly professional work on live DC.
If the panel voltage looks comfortably normal yet 122 keeps appearing, the problem is inside the box: bus capacitors or sensing circuits. Say that when you call, so the visit is planned as a hardware diagnosis — and possible board-level service — rather than a string check.
Frequently asked questions
Can cold weather really cause this?
Yes — it's one of the best-understood triggers. Solar panel voltage rises as temperature drops, so a string designed close to the limit in summer can exceed it on a freezing, sunny morning. If your 122s cluster on cold dawns, that's almost certainly the story.
How do I check my PV voltage?
Many Growatt displays show it — look for a PV or DC voltage readout in the menus. Compare it against the 'max DC voltage' figure on the inverter's nameplate or datasheet. Read it, write it down, and hand the numbers to your installer; don't touch any wiring.
What's the difference between Error 122 and PV Voltage High?
PV Voltage High is specifically the panel input exceeding the inverter's maximum DC rating. Error 122 is about the internal DC bus, which can go out of range from high input, low input, or an internal fault. They overlap but they aren't the same fault.
Is my inverter in danger?
The shutdown itself is the protection — the inverter refuses to run its power stage outside safe limits. The risk is to the equipment if it kept running, which it won't. Your job is just to get the string or the hardware checked before re-energizing.
Need a professional?
This fault may need professional diagnosis. Contact a qualified solar electrician in your area.