Growatt Inverter Output High DCI — Causes and Safe Steps
Output High DCI means your Growatt inverter detected too much DC current leaking into its AC output — it shows as Error 402 on the display. Solar inverters must feed the grid pure alternating current, so the inverter faults and stops rather than keep running. Restart it once; if the message returns, contact Growatt or your installer.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
DCI stands for DC injection — the small DC component that can ride along on the AC current your inverter feeds to the grid. In a healthy inverter this is essentially zero. Grid standards worldwide allow only a tiny amount, because even a modest DC offset can saturate distribution transformers, overheat neutral conductors, and corrode grounded equipment.
Growatt's official fault table lists this condition as "Error 402 — Output High DCI": the inverter's monitoring measured a DC component above the permitted limit and raised a fault. The response is deliberately strict — the inverter stops feeding power. That shutdown is the protection working, not the problem. It prevents a misbehaving output stage from pushing DC onto the grid and protects both your system and the network.
A single, non-recurring event can be a transient spike — a grid disturbance or a momentary measurement upset that clears with a restart. The manual's own guidance is brief and telling: restart the inverter, and if the problem still exists, contact Growatt. A fault that returns after a restart is not transient. It indicates something wrong in the inverter's output regulation or measurement chain, and that is strictly professional diagnostic territory — the output stage and grid connection are not homeowner-serviceable.
What is this downtime costing you?
Rough estimate while your system isn't producing. Adjust the numbers to match your setup.
≈ – kWh of lost production per day.
Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.
Common causes
- ["An internal control or measurement fault in the inverter's output stage — the most common cause of a recurring DCI fault.", "A grid-side disturbance upsetting the inverter's output regulation for a moment, producing a one-off trip.", 'Aging or failing output-stage components drifting out of calibration over years of operation.', 'A transient current spike during unusual grid conditions that clears completely on restart.', 'Firmware or sensing anomalies misreporting the DC component — diagnosable only by qualified service.']
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 1 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Contact Growatt service or your installer if Error 402 reappears after a restart, appears frequently, or the inverter will not stay running. The manual's own instruction is 'restart the inverter, if problem still exist, contact Growatt' — there is no deeper homeowner procedure. DC-injection faults involve the inverter's output stage and its grid connection, so diagnosis and any repair are strictly professional work. Never open the inverter casing: it contains lethal voltages and opening it voids the warranty.
Frequently asked questions
What does DCI actually stand for?
DC injection — the DC component present in the AC output current. Grid standards permit only a tiny amount; "Output High DCI" means that limit was exceeded and the inverter shut down to stay compliant.
Can high DCI damage my home appliances?
The inverter shuts down before it becomes a problem — that is the point of the protection. But a recurring fault means something is wrong inside the inverter's output stage, so don't ignore it.
Is it safe to restart the inverter myself?
Yes — operating the external AC disconnect and DC isolator as the manual describes is safe and is exactly what Growatt recommends as the first step. What is not safe is opening the inverter or touching any wiring.
Will this fault clear on its own?
Sometimes a transient spike clears with a single restart. A fault that comes back after restarting is not transient — that is the signal to get it serviced.
Need a professional?
This fault may need professional diagnosis. Contact a qualified solar electrician in your area.
Sources: meaning and troubleshooting verified against the manufacturer's documentation — Growatt MIN 2.5-6K TL-X2 User Manual (GR-UM-293-A-01), section 11.4 Inverter fault — Error 402 'Output High DCI' (hg.growatt.com)