Solis Inverter ILeak-PRO 01-04 — What the Leakage Levels Mean
ILeak-PRO 01, 02, 03, or 04 means your Solis inverter's leakage-current protection has tripped — it detected electric current leaking to ground somewhere in the system and shut down to stay safe. The number tells you which sensitivity stage tripped: 01 at 30mA, 02 at 60mA, 03 at 150mA, 04 higher still. Do not touch the equipment; note the code and call your installer.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
Every solar array operates at hundreds of volts DC, and all of that electricity is supposed to stay inside its wires — panels, cables, and connectors are all meant to be isolated from earth. Your Solis inverter watches that isolation continuously with residual-current monitoring. "ILeak-PRO" is that protection doing its job: it sensed current leaking to ground and tripped before the situation could become dangerous.
The 01–04 suffix is what makes this message useful. Solis implements the protection in four staged thresholds, documented in the official troubleshooting table: ILeak-PRO01 trips at 30mA of leakage current, PRO02 at 60mA, PRO03 at 150mA, and PRO04 at the highest level. A higher number means a larger leakage current was detected — so a PRO 03 or 04 is a louder alarm than a PRO 01, though all of them stop the inverter.
Two related messages are worth distinguishing. "ILeak-FAULT" is the general fault message some Solis models display when leakage protection has shut the inverter down — treat it the same way. "ILeak_Check" is different: it means the leakage-current sensor itself has failed, which also needs a technician but is a sensing problem rather than a confirmed leak.
The single most common transient cause is moisture — rain, condensation, or damp getting into the array or cabling. A PRO 01 that appears during a downpour and clears as things dry out is the classic harmless pattern. Anything persistent, anything at the higher stages, or anything accompanied by visible damage is not harmless and needs your installer.
What is this downtime costing you?
Rough estimate while your system isn't producing. Adjust the numbers to match your setup.
≈ – kWh of lost production per day.
Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.
Common causes
- ['Moisture or water ingress — rain, condensation, or flooding around the array, cabling, or inverter; the most common transient cause, especially for PRO 01.', 'Damaged cable insulation — UV-aged, rodent-chewed, abraded, or pinched DC or AC cables letting current escape.', 'A cracked panel backsheet or failing panel allowing leakage from the cells to the frame.', 'Degraded connectors, combiner-box issues, or loose terminals exposed to the weather.', 'Grounding problems — poor, corroded, or disconnected earth connections, which is why the manual says to verify your grounding.']
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 1 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Call your installer promptly if you see ILeak-PRO 03 or 04, if any subcode persists in dry weather after a restart, or if there is visible damage, scorch marks, or a burning smell. Leakage-current faults sit squarely in shock-and-fire territory: the manual's remedy is to check current leakage to ground, verify grounding, and confirm all wiring is sound — all qualified-person work. Treat it as an emergency if there is smoke, sparking, or a burning smell: switch off via the external disconnects and call your installer or emergency services. Never open the inverter or handle array cabling yourself.
Frequently asked questions
What do the numbers 01 to 04 actually mean?
They are staged protection thresholds: 01 trips at 30mA of leakage current, 02 at 60mA, 03 at 150mA, and 04 at the highest level. A higher number means a larger leakage current was detected.
What is the difference between ILeak-PRO and ILeak-FAULT?
ILeak-PRO 01–04 tells you which protection stage tripped; ILeak-FAULT is the general fault message some Solis models show when leakage protection has shut the inverter down. Treat them the same way: hands off, call your installer.
It rained heavily and now I see ILeak-PRO 01 — should I worry?
Moisture is the most common transient cause. If 01 clears as things dry out and does not return, it was most likely just water. If it persists in dry weather, get it checked.
Can I keep running the system with an ILeak-PRO code showing?
You don't get the choice — the inverter shuts itself down when protection trips. Do not try to bypass or ignore it; the protection tripped for a reason.
Is this an emergency?
If there is smoke, sparking, or a burning smell, treat it as one: switch off via the external disconnects and call your installer or emergency services. A lone ILeak-PRO code with no other symptoms needs a prompt — not panicked — call to your installer.
Need a professional?
This fault may need professional diagnosis. Contact a qualified solar electrician in your area.
Sources: meaning and troubleshooting verified against the manufacturer's documentation — Solis S6 Series Hybrid Inverter User Manual (V1.2, 06/2025), Table 7.1 — ILeak-PRO01 (30mA) / PRO02 (60mA) / PRO03 (150mA) / PRO04 'Leakage current failure' (solisinverters.com)