Critical What does this mean?

A safety-rated fault — there may be a risk of electric shock, fire, or equipment damage. Do not try to fix this yourself. Call a qualified electrician.

SolarEdge Inverter Error 150 — Arc Fault Detected Explained

SolarEdge Inverter Error 150 — Arc Fault Detected Explained

Error 150 means Arc Fault Detected: your inverter's arc-fault circuit interrupter sensed the electrical signature of a DC arc somewhere in the array and shut the system down. This is a fire-protection trip — treat it as one. The same fault shows as 147 or 151 on older firmware and as 2x96 / 2x97 / 3x11 (newest single-phase: 18xC) on newer firmware. SolarEdge's documentation points to its 'Inverter Arc Detection and Interruption Troubleshooting' guide. Do not just reset and ignore it; an arc that is still physically present will simply strike again.

What should I do first?

Two quick questions — we'll point you to the right starting point.

Is this code still showing on your inverter's display?

What this code means

A DC arc is current jumping a small gap in a damaged or loose connection — a cracked MC4 connector, a chafed cable, a failing junction box. Unlike household AC, direct current has no zero-crossing to snuff the arc out, so once struck it sustains itself, pouring heat into the fault point. That is how array fires start — and why inverters carry arc-fault circuit interrupters (AFCI) that listen for arcing's high-frequency noise signature and kill production instantly.

Error 150 is that protection firing: 147, 150, or 151 on older single-phase firmware; 2x96, 2x97, 3x11 on newer; 18xC on the newest single-phase generation (three-phase: 8xC / 8xBA). Do not confuse these with the self-test codes — 152, 2x98, or 18x8D — which mean the detector's own wake-up self-test failed, a different problem.

The critical point: an arc fault trip latches for a reason. The loose connector or damaged wire that struck the arc is still on your roof after a reset — restarting without inspection re-energizes the same damaged connection and invites a restrike. SolarEdge's arc-detection documentation describes the manual AFCI test and restart procedure, but every path through it assumes the array has been inspected.

With fire rather than lost production at stake, this code joins isolation and ground-current faults in the small group where 'wait and see' is wrong and a same-day professional visit is right.

What is this downtime costing you?

Rough estimate while your system isn't producing. Adjust the numbers to match your setup.

–per day
–per week
–per 30 days

≈ – kWh of lost production per day.

Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.

Common causes

  • A loose, corroded, or improperly mated DC connector in the array — the single most common arc source. MC4-style connectors that were never fully latched, have worked loose with thermal cycling, or have corroded contacts arc under load.
  • Damaged cable insulation — pinched during installation, abraded against a mounting rail, or chewed by rodents — exposing conductor that arcs to nearby metalwork or across the breach.
  • A failing component — a cracked panel junction box, a dying optimizer, a compromised DC isolator — developing an internal gap that arcs as current flows.
  • A nuisance trip from electrical noise. Rare and last: the detector is sensitive by design, and only SolarEdge support, with the inverter's logs, can distinguish a false positive from a real arc.

Safe steps to try

Work top to bottom, ticking off each step as you complete it. 0 of 4 done.

Is your inverter still under warranty?

Before paying for a repair, check — your installer may fix this free.

Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.

When to call an electrician

Call your installer immediately — same day. Locating the arc source means controlled inspection of every string, connector, and optimizer per SolarEdge's 'Inverter Arc Detection and Interruption Troubleshooting' procedure. Never open DC connectors yourself, never disconnect strings under load to 'find' the arc, and never run the system with a recurring arc code while waiting for a convenient appointment.

Frequently asked questions

Can I just reset the inverter and keep producing?

No — not without inspection. The defect that caused the arc is still physically present, and re-energizing it invites a restrike. The documented restart procedure assumes the array has been checked first.

What is the difference between error 150 and error 152?

Error 150 (and 147/151) means the detector found a real arc signature and tripped. Error 152 (2x98 / 18x8D on newer firmware) means the arc detector's own self-test failed at wake-up — a fault in the detector, not a detected arc. Both need professional attention, but they are different problems.

Is my roof on fire?

Almost certainly not — the AFCI tripped precisely to prevent that. But the code means arcing conditions existed, so treat it seriously: inspect from a safe distance, call your installer the same day, and call emergency services if you see smoke or smell burning.

Will an arc fault clear on its own like a moisture-related isolation fault?

No. Moisture dries; a damaged connector does not heal. An arc code that 'clears' after a reset is silenced, not resolved.

How is this different from an isolation fault (error 25)?

An isolation fault means current may be leaking to earth — the inverter refuses to start as a precaution. An arc fault means the detector heard actual arcing — an active, heat-producing event. Both are Critical, but the arc code demands the faster response.

Need a professional?

This fault is a safety risk — do not attempt to fix it yourself. Contact a qualified solar electrician in your area.

Sources: meaning and troubleshooting verified against the manufacturer's documentation — SolarEdge 'Troubleshooting SolarEdge Systems, Addendum (North America)' — Error Codes table, Arc Fault Detected row (single-phase CPU v3.18xx: 147, 150, 151 → v3.19xx: 2x96, 2x97, 3x11; 'Refer to Inverter Arc Detection and Interruption Troubleshooting' guide MAN-01-00332-1.1); SolarEdge 'Application Note — Inverter Arc Detection in SolarEdge Systems' (single-phase arc codes 18xC / 3x11; AFCI self-test failure 18x8D; manual AFCI test and restart procedure). Note: Knowledge Center direct access was bot-blocked (HTTP 403); verification used verbatim official-document text via indexed mirrors, cross-checked across multiple hosts.