Warning What does this mean?

Your system is down or running degraded, but this is not an immediate safety danger. Work through the safe steps below.

Solis Inverter UN-G-V Error — Practical Steps to Fix It Safely

Solis Inverter UN-G-V Error — Practical Steps to Fix It Safely

Grid voltage fell below your Solis inverter's safe limit, so it disconnected. This is the mirror image of OV-G-V — brownouts, weak rural grids, or a poor AC connection on your side.

What should I do first?

Two quick questions — we'll point you to the right starting point.

Is this code still showing on your inverter's display?

What this code means

UN-G-V means under grid voltage — the mirror image of OV-G-V. When the AC grid sags below the protection threshold, your Solis stops feeding power and raises this alarm, then reconnects automatically once voltage recovers. The variants 01 and 02 cover different levels of the sag.

Two very different worlds produce this code, and telling them apart is the whole game. In the first, the entire street sags: brownouts during evening peak demand, or a weak rural feeder at the end of a long line. In the second, the grid is healthy but your own AC connection is not — a loose or corroded terminal, or an undersized cable, drops voltage before it reaches the inverter, and the drop gets worse as current rises.

The clues are timing and company. Faults clustering on hot evenings, with flickering house lights and neighbors seeing the same thing, belong to the grid. Random trips with a steady grid, or faults that worsen as your system exports harder, belong to your wiring. Note both the clock and the symptoms; that pair is what separates a utility report from an installer visit.

What is this downtime costing you?

Rough estimate while your system isn't producing. Adjust the numbers to match your setup.

–per day
–per week
–per 30 days

≈ – kWh of lost production per day.

Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.

Common causes

  • A utility brownout during peak demand. Hot evenings, when air-conditioning loads surge across the suburb, are the classic window.
  • A weak rural grid. Long feeders at the end of the line have naturally high impedance and sag noticeably under load.
  • A high-resistance AC connection on your side — a loose or corroded terminal that drops voltage before it reaches the inverter, worse the more current flows.
  • An undersized AC cable run between the inverter and the switchboard.
  • Protection limits set tighter than local conditions warrant. Only the installer can assess and adjust these.

Safe steps to try

Work top to bottom, ticking off each step as you complete it. 0 of 5 done.

Is your inverter still under warranty?

Before paying for a repair, check — your installer may fix this free.

Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.

When to call an electrician

Call your installer if the fault recurs without any area-wide cause, or if it is getting more frequent — a degrading connection gets worse over time, never better. The technician measures voltage at the inverter's terminals under load and compares it with what the meter sees; a meaningful gap between the two means the voltage is being lost inside your AC run, and they will check terminal tightness, contact condition, and cable sizing. If instead the whole street sags every evening, that is the distributor's network to reinforce — and a dated log of the sags is what gets a network fault investigated rather than filed away.

Frequently asked questions

Will it fix itself?

Usually, yes. The inverter reconnects automatically once grid voltage recovers. The question is never whether one event clears — it is whether the events keep coming, because each one is lost generation.

Is under-voltage harmful to my system?

The inverter protects itself by disconnecting, so there is no damage risk from the sag itself. The cost is purely production: a system that drops out every evening peak is a system underperforming its design.

My lights flicker when this happens — is it related?

Yes, very likely. Flickering lights plus UN-G-V means the supply itself is weak or unstable, not just the inverter's corner of it. Note the times both happen and report the pair together — to the installer, or to the utility if the street shares the symptom.

Why does it mostly happen in the evenings?

Peak demand drags voltage down, and long rural feeders feel it most. An evening-only rhythm points at the grid; random daytime trips point at your own AC connection.

Need a professional?

This fault may need professional diagnosis. Contact a qualified solar electrician in your area.

Sources: meaning and troubleshooting verified against the manufacturer's documentation — Solis S5-GR3P(3-13)K Three Phase Inverter User Manual (Ginlong Solis), Table 9.1