Solis Inverter OV-TEM Error — What to Do Next
Your Solis inverter is overheating and has cut output or shut down to protect itself. The cause is almost always the installation environment — sun, airflow, clearance — rather than a faulty unit.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
OV-TEM means over temperature. When internal temperatures exceed safe limits, your Solis first reduces its output — derating — and shuts down entirely if the heat keeps climbing. It resumes automatically as it cools, which is why owners often see a daily rhythm: strong mornings, a sagging afternoon, recovery toward evening.
Nine times out of ten this is an installation-environment story, not a faulty inverter. The usual suspects are direct afternoon sun on the enclosure, airflow blocked by stored items or overgrown vegetation, a heatsink packed with dust, or a cooling fan that has quietly failed. Electronics and heat are old enemies, and an inverter baking in a sun-trap will derate exactly as designed.
Do not be reassured just because every event “clears itself.” Repeated thermal cycling stresses components and shortens the unit's life, and every derated afternoon is generation you paid for and did not get. A system that overheats on mild spring days — not just heatwaves — has a ventilation or placement problem that deserves a proper fix.
What is this downtime costing you?
Rough estimate while your system isn't producing. Adjust the numbers to match your setup.
≈ – kWh of lost production per day.
Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.
Common causes
- Direct afternoon sun beating on the enclosure through the hottest part of the day.
- Blocked airflow — items stored against the unit, or vegetation grown up around it.
- A heatsink clogged with dust, cobwebs, or leaf litter, unable to shed heat.
- A failed or failing cooling fan that only shows itself under thermal load.
- Mounting with inadequate clearance, such as inside an unventilated box or hard against a heat-radiating wall.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 5 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Call your installer if over-temperature trips repeat, especially outside heatwaves — a fan that fails only under load or a heatsink packed with dust will not fix itself. The technician checks fan operation, cleans the heatsink, and verifies the mounting clearances against the manual. If the unit sits in unavoidable afternoon sun, the proper remedies are relocation or a purpose-built shade structure — never a draped cover, which traps heat and makes things worse. Treat repeated summer derating as lost production with a fixable cause, not as weather you simply endure.
Frequently asked questions
Will overheating damage my inverter?
It protects itself by derating first — reducing output as temperature climbs — and shutting down if it keeps rising. But chronic overheating shortens component life, so a unit that cooks every summer is aging faster than it should.
Can I cool it down myself?
You can clear obstructions and confirm airflow — that part is yours. Never spray water on it, never drape anything over it, and never open the casing. Real shade means proper placement or a purpose-built sunshade fitted by your installer, not a cover that traps heat.
Will the inverter warn me before shutting down?
Often, yes. Many Solis inverters derate before they trip, so a production dip on hot afternoons is the early warning and OV-TEM is the lockout. If you see that daily dip-then-trip rhythm, the environment — not the electronics — is the story.
Why does it always happen at the same time each afternoon?
Because that is when sun position and peak ambient heat coincide. A fault with a strict afternoon rhythm is the clearest possible pointer at the installation environment rather than a failing component.
Need a professional?
This fault may need professional diagnosis. Contact a qualified solar electrician in your area.