Warning What does this mean?

Your system is down or running degraded, but this is not an immediate safety danger. Work through the safe steps below.

Solis Inverter G-IMP Error — A Homeowner’s Troubleshooting Guide

Solis Inverter G-IMP Error — A Homeowner’s Troubleshooting Guide

The grid connection looks too “soft” — high impedance — for your Solis inverter to export into safely, so it has stopped feeding power. The cause is usually the local network or your AC cable run, not the inverter itself.

What should I do first?

Two quick questions — we'll point you to the right starting point.

Is this code still showing on your inverter's display?

What this code means

G-IMP means high grid impedance. Impedance is, roughly, how “soft” the grid connection is — its electrical resistance to the power your inverter is trying to push in. Pushing current through a high-impedance connection forces the local voltage upward, which is why G-IMP and OV-G-V are close cousins; some systems log both, and fixing the impedance often clears the voltage trips too.

The resistance can live in two places. It may be the network itself: long rural feeders are naturally high-impedance, and nothing about your installation is at fault. Or it may be your side of the meter: an undersized or over-long AC cable, or a loose terminal adding resistance at a connection point. The timing gives the game away — faults that appear at high-export times like sunny midday, when the inverter is pushing hardest and voltage rise is worst, are the textbook impedance signature.

This is not a homeowner-diagnosable code beyond reading that pattern. Confirming high impedance takes proper test instruments at the inverter terminals, and anything involving AC terminations belongs to a professional.

What is this downtime costing you?

Rough estimate while your system isn't producing. Adjust the numbers to match your setup.

–per day
–per week
–per 30 days

≈ – kWh of lost production per day.

Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.

Common causes

  • A long rural feeder with naturally high network impedance. At the end of the line, the grid is simply “softer.”
  • An undersized AC cable between the inverter and the switchboard.
  • An over-long cable run amplifying what would otherwise be a marginal cross-section.
  • A loose or corroded AC terminal adding resistance at a connection point.
  • Recent network changes — new transformer loading or a reconfiguration — raising local impedance.

Safe steps to try

Work top to bottom, ticking off each step as you complete it. 0 of 5 done.

Is your inverter still under warranty?

Before paying for a repair, check — your installer may fix this free.

Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.

When to call an electrician

Call your installer — high impedance is never homeowner-fixable. The technician measures the actual grid impedance at the inverter terminals with proper test gear, inspects the AC cable's cross-section and run length against the design, and checks terminal tightness at both ends of the run. Remedies range from re-terminating a loose connection to upsizing the AC cable. And if the measurement shows the network itself is the cause — a soft rural feeder, for instance — that documented reading is what the distributor needs before it will act on the network side.

Frequently asked questions

Does G-IMP mean my inverter is broken?

No. It means the inverter is refusing to feed into a grid connection it considers unsafe — the inverter is the messenger, not the patient. The cause sits in the wiring or the network, not in the unit's electronics.

Will restarting fix it?

One restart is worth trying for a transient event. But persistent G-IMP is a wiring or network condition, and no amount of restarting changes impedance. If it keeps returning, the measurement — not the reset — is what you need.

Is high grid impedance my utility's fault?

Sometimes. Long rural feeders have naturally high impedance, and there is nothing wrong with your installation in that case. But an undersized AC cable on your side of the meter causes exactly the same reading — which is why a professional needs to measure and separate the two.

Why does it mostly trip around midday?

Because midday is when export current is highest, and voltage rise across any resistance is worst at high current. A fault that appears with the midday export peak and vanishes toward evening is impedance behaving exactly as physics says it should.

Need a professional?

This fault may need professional diagnosis. Contact a qualified solar electrician in your area.

Sources: meaning and troubleshooting verified against the manufacturer's documentation — Solis S5-GR3P(3-13)K Three Phase Inverter User Manual (Ginlong Solis), Table 9.1