Huawei

Huawei Error Codes

11 diagnostic articles for Huawei inverters — verified against manufacturer documentation.

Huawei Inverter Alarm 2069 — Battery Reverse Connection Explained
Critical

Huawei Inverter Alarm 2069 — Battery Reverse Connection Explained

Alarm 2069 on a Huawei SUN2000 means the inverter has detected that the battery…

Read diagnosis →
Huawei Inverter Alarms 2036 and 2037 When Grid Frequency Trips
Warning

Huawei Inverter Alarms 2036 and 2037 When Grid Frequency Trips

Huawei alarm 2036 (grid overfrequency) and 2037 (grid underfrequency) mean the actual grid frequency…

Read diagnosis →
Huawei Inverter Alarm 2068 — Battery Abnormal and How to Clear It
Info

Huawei Inverter Alarm 2068 — Battery Abnormal and How to Clear It

Alarm 2068 on your Huawei SUN2000 means there is a problem with the connected…

Read diagnosis →
Huawei Inverter Alarm 2070 — Active Islanding Detection Explained
Warning

Huawei Inverter Alarm 2070 — Active Islanding Detection Explained

Alarm 2070 is Huawei's “Active Islanding” alarm — a Major-severity alarm meaning your SUN2000…

Read diagnosis →
Huawei Inverter AFCI 3003 — When the Arc-Fault Alarm Trips
Critical

Huawei Inverter AFCI 3003 — When the Arc-Fault Alarm Trips

Your Huawei SUN2000 has detected an electric arc somewhere in the DC wiring between…

Read diagnosis →
Huawei Inverter Alarm 2063 — Overtemperature and How to Respond
Warning

Huawei Inverter Alarm 2063 — Overtemperature and How to Respond

Alarm 2063 means the inverter cabinet has gotten too hot. Huawei lists three possible…

Read diagnosis →
Huawei Inverter Alarm 2035 — What Causes Unbalanced Grid Voltage?
Warning

Huawei Inverter Alarm 2035 — What Causes Unbalanced Grid Voltage?

Alarm 2035 means the difference between your three grid phase voltages has exceeded the…

Read diagnosis →
Huawei Inverter Alarm 2034 — Grid Overvoltage and HVRT Explained
Warning

Huawei Inverter Alarm 2034 — Grid Overvoltage and HVRT Explained

Alarm 2034 means the grid voltage rose above the upper threshold — or stayed…

Read diagnosis →
Huawei Inverter Alarm 2051 — Abnormal Residual Current Explained
Critical

Huawei Inverter Alarm 2051 — Abnormal Residual Current Explained

Alarm 2051 means your Huawei SUN2000 detected abnormal residual current — small amounts of…

Read diagnosis →
Huawei Inverter Alarm 2061 — Why Your Grounding Alarm Tripped
Critical

Huawei Inverter Alarm 2061 — Why Your Grounding Alarm Tripped

Alarm 2061 means your Huawei SUN2000 found a problem with its grounding — typically…

Read diagnosis →