Warning What does this mean?

Your system is down or running degraded, but this is not an immediate safety danger. Work through the safe steps below.

Growatt Inverter Error 100 — A Homeowner’s Troubleshooting Guide

Growatt Inverter Error 100 — A Homeowner’s Troubleshooting Guide

Error 100 means the inverter's internal 2.5-volt reference — the baseline every measurement is checked against — has failed. The inverter can't trust its own readings, so it shuts down. Try one restart; if 100 returns, the unit needs professional service.

What should I do first?

Two quick questions — we'll point you to the right starting point.

Is this code still showing on your inverter's display?

What this code means

An inverter makes hundreds of safety decisions a minute — is the grid voltage in range, is the panel voltage safe, is any current leaking? Every one of those decisions depends on measurements, and every measurement depends on a stable baseline: a precise 2.5-volt reference deep inside the control board. Think of it as the ruler everything else is measured with.

Error 100 means that ruler is broken. Growatt's troubleshooting guide describes it as an internal reference voltage fault, and the consequence is straightforward: with no trustworthy baseline, no measurement can be trusted, so no safe operation is possible. The inverter shuts down rather than make safety decisions from bad data.

This is purely an internal hardware matter. It has nothing to do with your panels, your wiring, or the grid — the same fault would appear with perfect sunshine and a perfect grid, because the failure is inside the box. That's also why there's no environmental fix: no amount of waiting, cleaning panels, or checking breakers addresses a failed reference circuit. Growatt's remedy is equally direct — restart, and if the error persists, contact service to replace the inverter.

What is this downtime costing you?

Rough estimate while your system isn't producing. Adjust the numbers to match your setup.

–per day
–per week
–per 30 days

≈ – kWh of lost production per day.

Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.

Common causes

  • Failure of the reference-voltage component itself — a small precision part on the control board that can simply fail, like any electronic component.
  • A wider control-board fault — the reference circuit shares the board with the processors, so board-level damage or aging can take the reference down with it.
  • Age-related degradation — years of heat and thermal cycling slowly wear electronics; precision circuits are often the first to drift out of tolerance.
  • Electrical stress from a surge or transient — a severe spike can damage sensitive low-voltage circuits while the rugged power stage survives untouched.
  • Sustained high internal temperatures — an inverter baking in direct sun with blocked ventilation ages its precision electronics faster; heat is the quiet accelerator behind many 'it just failed' board faults.

Safe steps to try

Work top to bottom, ticking off each step as you complete it. 0 of 4 done.

Is your inverter still under warranty?

Before paying for a repair, check — your installer may fix this free.

Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.

When to call an electrician

Call your installer or Growatt service as soon as Error 100 survives a restart. Growatt's official guidance is explicit: if the error still exists after restarting, contact service to replace the inverter. There is no adjustment, setting, or firmware fix for a failed reference circuit — it's a board-level fault, and the remedy is a replacement unit.

Have your install date and any warranty paperwork ready when you call. A technician will confirm the fault code, verify that it isn't a one-off glitch, and start the replacement process. Your panels, mounting, and wiring are all unaffected and will connect straight to the new unit.

Frequently asked questions

What is the 2.5V reference, in plain terms?

It's the inverter's internal yardstick. Every voltage and current measurement is compared against this one precise voltage. When the yardstick itself breaks, the inverter can't verify anything is safe — so it stops. That's the whole story of Error 100.

Can it be repaired, or do I need a new inverter?

Growatt's troubleshooting says to replace the unit if a restart doesn't clear it. The reference circuit is part of the control board; it's not a user-serviceable part, and field repair of board-level precision circuits isn't practical.

Are my panels and wiring at risk?

No. The inverter fails safe by shutting down, and the fault is entirely internal. Your array, cabling, and switchboard are unaffected — they'll work normally with the replacement inverter.

How long will I be without solar?

Until the unit is serviced or replaced, the system produces nothing and your home runs on grid power. Call promptly: the sooner the fault is logged with your installer or Growatt, the sooner the replacement process starts.

Need a professional?

This fault may need professional diagnosis. Contact a qualified solar electrician in your area.

Sources: meaning and troubleshooting verified against the manufacturer's documentation — Troubleshooting for Growatt TL&MTL (Ver1.2) 2013-7-15, Growatt New Energy ('it means the internal reference voltage fault. Restart the inverter, if the error still exists, please contact Growatt service to replace an inverter.')