Growatt Inverter Error 116 — What It Means & What to Check
Error 116 means the inverter failed while reading from or writing to its EEPROM — the memory chip holding its settings and calibration data. Without reliable memory it can't operate safely, so it shuts down. Note what time it appears; Growatt asks about morning occurrences.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
An inverter needs to remember things: its configuration, calibration values, country grid settings, lifetime energy counters. That long-term memory lives on a small chip called EEPROM, which keeps its contents even when the power is off — unlike the working memory that forgets everything at shutdown.
Error 116 means the inverter tried to read from or write to that chip and failed. Growatt's troubleshooting guide describes it plainly as a failure in reading or writing EEPROM. With its settings and calibration data unreliable, the inverter can't trust its own configuration — it might be operating against corrupted grid limits or wrong calibration — so it shuts down instead.
Here's the distinctive part: Growatt's guide specifically asks whether the error appears in the morning. At dawn the inverter boots from cold into weak, rising sunlight, and that low-light startup seems to be when marginal memory or configuration issues surface. A 116 that appears only in the morning and clears as the day brightens tells a different story than one that strikes at noon — and Growatt wants your panel configuration details in the morning-only case, which suggests the interaction between startup conditions and stored settings is a known pattern, not a coincidence.
What is this downtime costing you?
Rough estimate while your system isn't producing. Adjust the numbers to match your setup.
≈ – kWh of lost production per day.
Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.
Common causes
- A failing EEPROM chip — the memory itself can wear out or fail, especially after years of write cycles and heat.
- A control-board fault — the EEPROM sits on the control board, so board-level damage can take the memory down with it.
- Corrupted stored data — the chip may be fine while its contents aren't; a bad write during a previous shutdown can leave settings the inverter can't make sense of.
- Marginal low-light startup conditions — the morning-only pattern Growatt flags, where weak dawn power during boot seems to expose a memory or configuration weakness that full daylight masks.
- Borderline-low supply voltage during dawn startup — the processor can boot before its internal supply rails are fully stable in very weak light, producing a memory misread that never happens once the day brightens.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 4 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Call your installer or Growatt service if Error 116 appears at any time other than early morning, persists after a restart, or shows up daily. The likely remedy is a control-board replacement — the EEPROM isn't a separately serviceable part — and that's a technician job.
When you call, lead with the timing pattern: 'only in the morning, clears by mid-morning' versus 'throughout the day.' In the morning-only case, have your array details ready, because support will ask. In the all-day case, say so plainly — that pattern points to failed memory hardware, and the conversation moves straight to replacement.
Frequently asked questions
Why does Growatt care whether it happens in the morning?
Because their troubleshooting guide singles it out. Morning-only 116 seems tied to low-light startup conditions interacting with stored settings — a known pattern they diagnose differently, starting with your panel configuration rather than jumping to board replacement.
Will I lose my inverter's settings?
The settings live on the failing chip, which is precisely why the inverter stops — it can't verify its own configuration. A replacement board comes with fresh memory, and your installer reconfigures the new unit with the correct settings.
Can I reset the EEPROM myself?
No. It's board-level memory with no user access, and there's no button combination or menu option that repairs it. The official remedy is control-board replacement by qualified service.
If it clears by itself each morning, can I ignore it?
Don't. A memory fault that clears is still a memory fault — it's telling you the chip or its data is marginal, and marginal tends to become failed. Log the pattern and report it; catching it early beats a dead inverter in midsummer.
Need a professional?
This fault may need professional diagnosis. Contact a qualified solar electrician in your area.