Growatt Inverter Error 117 — What to Do Next
Error 117 means the inverter's self-test found a fault in its relay circuit — the relays that connect your system to the grid only when safe. The inverter won't feed power until it's resolved. One restart is worth trying; a persistent 117 means service.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
A grid-tied inverter must never energize the grid at the wrong moment — during an outage, for example, when lineworkers may be on the wires. The component that enforces this is the relay: an electromechanical switch between the inverter's power stage and your switchboard. Before the inverter feeds a single watt, and repeatedly during operation, it tests that the relays open and close exactly as commanded.
Error 117 means that self-test failed. The inverter detected something wrong in the relay circuit — a relay not responding, a contact in the wrong state, or the driver circuit that operates them misbehaving. Its response is absolute: no grid connection, no power production, until the fault is resolved.
Unlike codes tied to weather or the grid, a relay fault is about the inverter's own hardware. It won't improve with patience or sunshine. Growatt's troubleshooting guide is unusually blunt here: restart the inverter, and if the error still exists, contact Growatt service to replace the unit. That wording tells you this is treated as a hardware failure, not a condition to troubleshoot your way out of.
What is this downtime costing you?
Rough estimate while your system isn't producing. Adjust the numbers to match your setup.
≈ – kWh of lost production per day.
Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.
Common causes
- Relay wear or failure — relays are mechanical parts with moving contacts; after years of daily switching they can stick, pit, or fail to close fully.
- A voltage spike or surge — a nearby lightning strike or a sharp grid transient can damage the relay driver circuit or weld a contact.
- An internal control-board fault — the circuit that commands and senses the relays lives on the control board; if it fails, the relay test fails with it.
- A one-off electronic glitch — rare, but the reason Growatt allows one restart before declaring the unit faulty. If it was transient, the self-test passes on the next boot.
- Incorrect AC wiring from installation or later electrical work — miswired conductors can cause the relay self-test to fail its checks even though the relays themselves are healthy, which is why the fault sometimes traces back to the switchboard rather than the unit.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 4 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Call your installer or Growatt service as soon as Error 117 survives one restart. Growatt's own guidance ends there: the unit needs service or replacement, and there is no homeowner remedy beyond that single restart. Repeated resets won't repair a relay, and a relay that can't be trusted can't be trusted to keep the grid safe.
Expect the technician to confirm the fault, check the unit's warranty status, and arrange a replacement if the relay circuit is confirmed faulty. Keep your purchase and installation paperwork handy — for a relay failure on a relatively new unit, warranty coverage is the first thing to check.
Frequently asked questions
What exactly does the relay do?
It's the safety switch between your solar system and the grid. It connects the inverter only when grid conditions are safe and disconnects instantly during outages or faults. The inverter tests it constantly, and 117 means that test failed.
Can my home still run on solar while it shows?
No — the inverter produces nothing until the relay fault is resolved. Your house draws from the grid normally, so you'll have power; you just won't be generating.
Why only one restart — why not keep trying?
Because Growatt treats a persistent 117 as a hardware failure. Each extra power cycle stresses already-suspect components, and it can't repair worn contacts or a damaged driver circuit. One clean restart separates a glitch from a fault; after that, it's a service job.
Is this dangerous?
Not in the way an electrical fault is dangerous — the inverter is shut down and isolated. The danger would be a relay that failed silently and connected the grid unsafely, which is exactly what the self-test prevents. That's why the inverter is so uncompromising about it.
Need a professional?
This fault may need professional diagnosis. Contact a qualified solar electrician in your area.
Sources: meaning and troubleshooting verified against the manufacturer's documentation — Troubleshooting for Growatt TL&MTL (Ver1.2) 2013-7-15, Growatt New Energy ('There is something wrong with the relay circuit. Restart the inverter, if the error still exists, please contact Growatt service to replace an inverter.')