Critical What does this mean?
A safety-rated fault — there may be a risk of electric shock, fire, or equipment damage. Do not try to fix this yourself. Call a qualified electrician.
Growatt Inverter Error 119 — Is It Dangerous? What to Do Immediately
Error 119 means the inverter's self-test found a possible fault in its internal GFCI device — the shock-protection component that disconnects the system on a ground fault. Treat this seriously: one restart is permitted, then it's a professional job.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
Every grid-tied inverter has a ground-fault safety system. Normally the current flowing out to your panels matches the current coming back; if some of it starts leaking to earth — through damaged insulation, moisture, or a cracked panel — the GFCI (ground-fault circuit interrupter) function detects the imbalance and disconnects the inverter in a fraction of a second. It's the device standing between a wiring fault and an electric shock.
Error 119 is one level more serious than a detected ground fault: it means the inverter's self-test found something wrong with the GFCI device itself. Not the wiring — the protector. Growatt's troubleshooting guide phrases it carefully ('something may be wrong with the GFCI device inside the inverter'), and the fault name in the manual is 'GFCI Device Damage.'
The practical meaning: the component that is supposed to keep you safe may not be working, and the inverter knows it. That's why the unit shuts down and stays down. A ground fault the inverter can't see is worse than one it can, because nothing would trip. So while the shutdown is inconvenient, it's the correct behavior — an inverter that doubts its own protection must not operate.
What is this downtime costing you?
Rough estimate while your system isn't producing. Adjust the numbers to match your setup.
≈ – kWh of lost production per day.
Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.
Common causes
- Failure of the internal GFCI sensing circuit — the current-sensing components or their electronics can fail with age or heat, and the self-test catches it.
- Moisture ingress reaching the sensing electronics — water inside the enclosure can disturb sensitive measurement circuits even without damaging power components.
- Component aging — years of thermal cycling slowly degrade electronics, and safety self-tests are designed to catch exactly this kind of drift.
- A severe electrical transient — a nearby lightning strike or major grid surge can damage delicate sensing circuits while leaving the rest of the inverter apparently fine.
- A latent manufacturing defect in the sensing components — rare, but the reason this fault occasionally appears on relatively new units with no history of surges or moisture.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 4 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Call your installer or Growatt service promptly — this one shouldn't wait for a convenient day. Because the fault concerns the shock-protection device itself, every reset is a gamble that the protection works this time, and Growatt's guidance is to replace the unit if the error persists after restarts.
Say the words 'GFCI device fault' when you call, so it's triaged correctly. The technician will verify the fault, confirm the internal safety circuit is compromised, and arrange a replacement inverter — this is a board-level safety failure, not something adjusted or repaired in the field. Keep the system off until then, and don't let anyone talk you into 'just resetting it daily' as a workaround.
Frequently asked questions
Is Error 119 actually dangerous?
Potentially, yes — and that's what makes it different from most codes. The GFCI is your shock protection; if the protector itself is faulty, a ground fault elsewhere in the system might not be caught. The inverter's shutdown is what keeps you safe, so respect it and keep the system off.
Why can't I just keep resetting it when it appears?
Because each reset asks a possibly-broken safety device to do its job again. Growatt's own guidance ends at replacement if the error persists. Repeated resets don't repair sensing electronics — they just postpone the service call while running without reliable protection.
Can I still use my panels for anything?
No. The inverter has shut itself down and must stay down until serviced. Your home runs on grid power as normal; only your solar generation is offline.
Will it go away on its own?
Very unlikely. This is an internal hardware self-test failure, not a weather or grid condition. It doesn't clear with sunshine or time — it clears with a service visit, and most likely a replacement unit.
Need a professional?
This fault is a safety risk — do not attempt to fix it yourself. Contact a qualified solar electrician in your area.
Sources: meaning and troubleshooting verified against the manufacturer's documentation — Troubleshooting for Growatt TL&MTL (Ver1.2) 2013-7-15, Growatt New Energy ('something may be wrong with the GFCI device inside the inverter'); fault name 'GFCI Device Damage' per Growatt TL User Manual 2012-08-17