Growatt Inverter Error 119: Meaning, Causes & Safe Fix
Error 119 means the inverter's internal GFCI safety device — the component that protects against electric shock from ground faults — may be damaged. Treat this as a safety issue and call a professional.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
GFCI (Ground Fault Circuit Interrupter) is the safety device that disconnects the inverter if it detects dangerous leakage current. Error 119 means the inverter's self-test found something wrong with this GFCI device itself — the very component that keeps you safe may not be working.What is this downtime costing you?
Rough estimate while your system isn't producing. Adjust the numbers to match your setup.
≈ – kWh of lost production per day.
Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.
Common causes
- Internal GFCI sensing circuit failure
- Moisture ingress affecting the sensing circuit
- Component aging
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 4 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Call your installer or Growatt service immediately if Error 119 appears more than transiently. Because this fault concerns the shock-protection device itself, do not keep resetting it — if it persists after restarts, Growatt's documentation states the inverter must be replaced.
Frequently asked questions
Is Error 119 dangerous?
Potentially, yes. The GFCI is what protects against electric shock from ground faults. If the device providing that protection is itself faulty, the system should be treated with caution until a professional checks it.
Can I keep using my solar panels with Error 119?
No. The inverter has shut itself down. Leave it off and get professional help.
Will the error go away on its own?
Unlikely — this indicates an internal hardware problem. Growatt's official guidance is to restart a few times, then replace the unit if the error persists.
Need a professional?
This fault is a safety risk — do not attempt to fix it yourself. Contact a qualified solar electrician in your area.
Sources: meaning and troubleshooting verified against the manufacturer's documentation — Troubleshooting for Growatt TL&MTL (Ver1.2) 2013-7-15, Growatt New Energy ('something may be wrong with the GFCI device inside the inverter'); fault name 'GFCI Device Damage' per Growatt TL User Manual 2012-08-17