Growatt Inverter Error 122: Meaning, Causes & Safe Fix
Error 122 means the inverter's internal DC bus voltage is out of range — often linked to the solar panel input voltage being too high or too low for the inverter's limits.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
The DC bus is the internal high-voltage stage that converts your panels' DC into grid-ready AC. Error 122 means this bus voltage has drifted outside its permitted range, so the inverter shuts down to protect itself.What is this downtime costing you?
Rough estimate while your system isn't producing. Adjust the numbers to match your setup.
≈ – kWh of lost production per day.
Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.
Common causes
- PV string voltage above the inverter's maximum DC input (too many panels in series)
- PV voltage below the operating range
- Internal bus capacitor or voltage-sensing fault
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 4 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Call your installer if Error 122 persists — especially if the PV voltage exceeds the inverter's maximum DC rating on its datasheet, the string may need rewiring (fewer panels per string), which is strictly an installer job. If voltages look normal but the error persists, contact Growatt service.
Frequently asked questions
Can cold weather cause Error 122?
Yes — solar panels produce higher voltage when cold. On a freezing bright morning, a string that is fine in summer can briefly exceed the inverter's limit.
How do I know my PV voltage?
Many Growatt inverters show it on the display (look for a PV voltage readout). Compare it to the 'max DC voltage' on your inverter's datasheet or nameplate — but do not touch any wiring.
Is Error 122 dangerous?
The inverter protects itself by shutting down. The risk is to the equipment, not to you — but the fix (changing panel wiring) must be done by a professional.