Critical What does this mean?

A safety-rated fault — there may be a risk of electric shock, fire, or equipment damage. Do not try to fix this yourself. Call a qualified electrician.

Solis Inverter GROUND-FAULT Error — When to Call an Electrician

Solis Inverter GROUND-FAULT Error — When to Call an Electrician

Your Solis inverter found a ground fault — part of the PV system is touching earth where it should not. This is a shock and fire risk: do not touch anything, and call a professional.

What should I do first?

Two quick questions — we'll point you to the right starting point.

Is this code still showing on your inverter's display?

What this code means

Ground-Fault means the inverter's insulation monitoring has found a ground fault on the PV side: part of the array is touching earth where it should not. Transformerless inverters like the Solis watch the electrical resistance between the panel array and earth continuously, and when that resistance drops — a cable chafed through on the mounting frame, a wet connector, a pinched wire — they raise this alarm and refuse to generate.

Note the refusal. Unlike a grid code that reconnects when conditions normalize, a ground fault does not self-heal, so the inverter stays locked out until the fault is physically found and fixed. That strictness is deliberate: an unintended current path to earth is both a shock hazard for anyone touching the array and a potential fire starter.

There is a recognizable weather rhythm to watch for. Faults that appear at dawn and disappear by mid-morning usually mean overnight dew bridging a damaged spot that dries as the sun climbs. Faults that arrive with rain and linger point to a more seriously compromised seal or cable. Either pattern is worth reporting verbatim — it narrows the technician's search considerably.

What is this downtime costing you?

Rough estimate while your system isn't producing. Adjust the numbers to match your setup.

–per day
–per week
–per 30 days

≈ – kWh of lost production per day.

Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.

Common causes

  • PV cable insulation cut or chafed where the cable rests on the mounting frame or a sharp roof edge.
  • Moisture inside an MC4 connector whose seal has cracked or aged.
  • A cable pinched during installation, with the insulation slowly failing under the pressure point.
  • Rodent or pest damage to cable sheathing in the roof space.
  • A damaged panel backsheet or failing junction box creating a leakage path from the cells to the frame.

Safe steps to try

Work top to bottom, ticking off each step as you complete it. 0 of 5 done.

Is your inverter still under warranty?

Before paying for a repair, check — your installer may fix this free.

Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.

When to call an electrician

Do not sit on this one — get your installer or an electrician out promptly. Ground faults are located by insulation-resistance testing, disconnecting strings one at a time until the faulty section reveals itself — work that means handling live DC conductors and belongs strictly to professionals. When you call, report the exact variant (01 or 02) and the pattern you observed: dawn-only, rain-linked, or constant. A dawn-and-dew pattern sends the technician straight to connectors and low-lying cable runs; a constant fault means a hard insulation failure somewhere in the array. Never try to find it by handling cables or connectors yourself.

Frequently asked questions

Will the system keep working with a ground fault?

No. The inverter refuses to generate until the fault is resolved — that lockout is the protection doing its job, not a malfunction. Any current finding its way to earth is treated as both a shock and a fire risk.

Can I find the faulty string myself?

No. Locating the faulty string means handling live DC conductors and using insulation test equipment — strictly installer work. Your job is to report the code accurately, not to hunt it.

Can rain or morning dew cause a ground fault?

Yes — moisture bridging a damaged connector or cable is one of the most common triggers. Faults that appear at dawn and vanish by mid-morning usually mean overnight dew finding a damaged spot that dries out later.

Is there a fire risk with a ground fault?

It can, under the wrong conditions — which is exactly why the inverter locks out instead of retrying. That lockout is also why you should not keep restarting past it: every reset is an attempt to re-energize a known-bad insulation path.

Need a professional?

This fault is a safety risk — do not attempt to fix it yourself. Contact a qualified solar electrician in your area.

Sources: meaning and troubleshooting verified against the manufacturer's documentation — Solis 4G Single Phase Inverter User Manual – US Version (Ginlong Solis), Table 8.1