Critical What does this mean?
A safety-rated fault — there may be a risk of electric shock, fire, or equipment damage. Do not try to fix this yourself. Call a qualified electrician.
Solis Inverter ILEAK-FAULT Error — Is It Dangerous?
Your Solis inverter measured excessive leakage current on the grid (AC) side and shut down. Like its PRO sibling this is a shock-safety trip — do not touch the equipment, and call a professional.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
ILeak-FAULT means high grid leakage current. Where ILeak-PRO is the protection trip, ILeak-FAULT is the measurement behind it: the inverter has detected excessive leakage current specifically on the grid (AC) side and shut down. The variants 01 through 04 are escalating thresholds, so a higher variant means a larger leak was measured.
The practical consequence of that “grid side” detail is where the investigation concentrates. The technician starts with the AC wiring, the outdoor isolator, and the AC terminals rather than the panel strings — though a thorough check covers both sides. Moisture ingress at an outdoor AC isolator that has lost its weather seal is the classic culprit, which is why this code loves wet weather.
Like all leakage trips, this one does not self-heal. A restart may clear the display if the moisture has dried, but the compromised seal, damaged cable, or loose terminal is still there, and the next rain brings the code back. The alarm staying latched is the system refusing to run on a known-bad insulation path.
What is this downtime costing you?
Rough estimate while your system isn't producing. Adjust the numbers to match your setup.
≈ – kWh of lost production per day.
Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.
Common causes
- Moisture inside the outdoor AC isolator or a junction box after rain. An isolator that has lost its weather seal is one of the most common triggers.
- Damaged AC cable insulation — abraded where the cable passes through the roof space, or chewed by pests.
- A loose AC terminal at the inverter or the switchboard, creating a leakage path at the connection point.
- A degraded surge-protection device or simply aging cable insulation after years of heat.
- Condensation inside enclosures in climates with wide day-to-night temperature swings, bridging terminals that are otherwise sound.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 5 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Make this a same-day call to your installer or an electrician — high grid leakage current is a shock hazard, and tracing it takes insulation testing with proper instruments. The technician megger-tests the AC run and the isolators, opens the outdoor isolator to check for moisture ingress and contact condition, and verifies terminal tightness at both ends of the run. Give them two facts when you call: the exact variant number, and whether the fault tracks wet weather. That pair of details often tells an experienced technician where the leak is before they even arrive.
Frequently asked questions
What is the difference between ILeak-FAULT and ILeak-PRO?
ILeak-FAULT reports high measured leakage current on the grid (AC) side; ILeak-PRO is the leakage-current protection trip. They are two lenses on the same hazard — stray current finding a path to earth — and both end with the inverter shut down and a professional required.
Can I keep resetting it to get through the day?
No. This is a safety protection, not a glitch, and it will keep tripping until the leak is found and fixed. Repeated resets just mask a shock hazard while losing you generation.
It only trips when it rains — what does that tell the technician?
Yes — rain and moisture are classic triggers for leakage faults. If the code appears in wet weather and clears when things dry out, tell your installer; the weather correlation is genuinely useful for locating the fault.
How long does the repair usually take?
Often a single visit once the leak is located. The finding is the work — insulation testing to isolate the faulty section — and the fix itself is usually a connector, an isolator, or a length of cable.
Need a professional?
This fault is a safety risk — do not attempt to fix it yourself. Contact a qualified solar electrician in your area.
Sources: meaning and troubleshooting verified against the manufacturer's documentation — Solis-1P(1-6)K-4G_V1.3 User Manual (Ginlong Solis), Table 8.1