Critical What does this mean?

A safety-rated fault — there may be a risk of electric shock, fire, or equipment damage. Do not try to fix this yourself. Call a qualified electrician.

Solis Inverter ILEAK-PRO Error — Urgent Causes and What to Do Now

Solis Inverter ILEAK-PRO Error — Urgent Causes and What to Do Now

Your Solis inverter detected leakage current — electricity escaping where it should not — and shut down as a safety protection. Treat the equipment as a potential shock hazard: do not touch anything, and get a professional out.

What should I do first?

Two quick questions — we'll point you to the right starting point.

Is this code still showing on your inverter's display?

What this code means

ILeak-PRO is the leakage-current protection trip. Your Solis continuously compares the current going out with the current coming back; any mismatch means some of it is leaking to earth — through damaged insulation, a wet connector, or a compromised cable. Cross the safety threshold and the inverter disconnects immediately. The variants 01 through 04 are escalating stages: a higher variant means a larger leak was detected.

This protection exists because leakage current is a shock and fire precursor. A small leak through damp insulation today can become a ground fault or an arc tomorrow, so the inverter treats any confirmed leak as a stop-work event rather than something to ride through.

Will it clear itself? Sometimes, in a narrow sense: if the leak was morning condensation inside a connector that dries by midday, a restart may hold. But a genuine insulation fault does not heal — it returns, often on a schedule tied to dew, rain, or humidity. A code that keeps coming back on damp mornings is not being oversensitive; it is detecting the same damaged spot under the same conditions.

What is this downtime costing you?

Rough estimate while your system isn't producing. Adjust the numbers to match your setup.

–per day
–per week
–per 30 days

≈ – kWh of lost production per day.

Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.

Common causes

  • Damp or damaged DC connector insulation letting moisture bridge current to earth. This is the most common field cause, and it often follows dew or rain.
  • Cable insulation chafed through where it rests against the mounting frame, a sharp roof edge, or a tile.
  • A loose AC or DC terminal creating a high-resistance path with measurable leakage.
  • A faulty internal cable connection inside the inverter — strictly technician territory.
  • Aging insulation after years of UV exposure and heat cycling, slowly losing its integrity.

Safe steps to try

Work top to bottom, ticking off each step as you complete it. 0 of 5 done.

Is your inverter still under warranty?

Before paying for a repair, check — your installer may fix this free.

Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.

When to call an electrician

Call your installer or an electrician immediately — a leakage-current trip is a safety protection, not a warning you monitor for a while. The technician locates the leak with insulation-resistance testing on each string and the AC run, inspects connectors and cable routing for damage or moisture ingress, and replaces whatever has failed. Tell them upfront whether the fault tracks wet weather or appears at random; that single detail decides where they start looking and can save an hour of diagnostic time. Never open the inverter yourself: there are no user-serviceable parts inside, and leakage faults can involve stored charge even with the unit shut down.

Frequently asked questions

Is this dangerous?

Yes. Leakage current means electricity may be taking an unintended path, which is a potential shock hazard — that is precisely why the inverter shut itself down instead of carrying on.

Can I restart the inverter?

Once, and only if everything looks, smells, and sounds completely normal — and write down that you did it. If the code returns, stop. A protection trip that repeats is a fault insisting on being found, not a glitch to be overridden.

It appeared after heavy rain — is that related?

Very likely. Moisture bridging a damaged connector or cable is a classic trigger, and faults that appear in wet weather and vanish when things dry out are telling the technician exactly where to look. Report the weather correlation when you call.

Will my inverter be OK after this?

The protection did its job, so the inverter itself is usually unharmed. But normal operation should not resume until a professional has found and fixed the leak — the shutdown was the easy part.

Need a professional?

This fault is a safety risk — do not attempt to fix it yourself. Contact a qualified solar electrician in your area.

Sources: meaning and troubleshooting verified against the manufacturer's documentation — Solis S5-GR3P(3-13)K Three Phase Inverter User Manual (Ginlong Solis), Table 9.1