Solis Inverter NO-GRID Error — Why It Happens and How to Respond
No grid voltage is reaching your Solis inverter, so it has shut down its output. In most cases the cause is a tripped AC breaker, a switched-off grid isolator, or a power outage — not a faulty inverter.
What should I do first?
Two quick questions — we'll point you to the right starting point.
Is this code still showing on your inverter's display?
Is your system producing power right now?
What this code means
NO-GRID means exactly what it says: the inverter cannot detect any grid voltage. A grid-tied inverter is legally required to see a live, stable grid before feeding power — this is the anti-islanding rule that keeps solar systems from energizing power lines while lineworkers may be repairing them. So when grid voltage vanishes, your Solis stops its output and raises this alarm. It is a status report, not a fault in the inverter itself.
The useful question is never “what's wrong with the inverter” but “where did the grid go.” If your whole house is dark, the answer is the utility network, and the inverter will simply wait it out. If the house has power but the inverter shows NO-GRID, the break sits between your switchboard and the inverter: a tripped breaker, a switched-off isolator, or a failed connection on that dedicated run. That split — house dark versus house lit — tells you in seconds whether to wait for the utility or call your installer.
Do not confuse this with UN-G-V, its close relative. UN-G-V means the grid is present but sagging below the limit; NO-GRID means there is nothing there at all. The distinction matters because the causes and the fixes are completely different.
What is this downtime costing you?
Rough estimate while your system isn't producing. Adjust the numbers to match your setup.
≈ – kWh of lost production per day.
Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.
Common causes
- The AC breaker feeding the inverter has tripped, cutting its grid connection while the rest of the house may still have power.
- The grid isolator switch beside the inverter is OFF — sometimes switched accidentally during garden work or by someone unfamiliar with the system.
- A utility outage has de-energized your street. In that case the inverter is simply doing its job.
- A loose AC terminal at the inverter, usually after years of thermal cycling or a poor original termination.
- Planned utility maintenance in your area. Distributors usually notify in advance, so check for notices or texts you may have missed.
Safe steps to try
Work top to bottom, ticking off each step as you complete it. 0 of 5 done.
Is your inverter still under warranty?
Before paying for a repair, check — your installer may fix this free.
Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.
When to call an electrician
Call an electrician if the inverter's AC breaker will not stay on after one reset, if you smell burning or see discoloration at the switchboard, or if any part of the circuit feels hot. Call your installer instead when the house has normal grid power everywhere else but the inverter still reports NO-GRID — that combination means the dedicated AC run to the inverter has failed somewhere, and the technician will check continuity, the isolator contacts, and the terminal condition at the inverter. Either way, do not open the inverter's AC wiring cover yourself; everything past the isolator is professional-only.
Frequently asked questions
Will a grid outage damage my inverter?
No. Grid-tied inverters are designed for exactly this: anti-islanding rules require them to shut down when the grid disappears, and they resume automatically when it returns. An outage is a rest for your inverter, not a threat to it.
Should I check whether my neighbors have power?
Yes, it is the fastest diagnostic you have. If the whole street is dark, it is a utility outage and there is nothing to fix on your side. If neighbors have power and you do not, the problem is inside your property.
The breaker tripped — can I just flip it back on?
Once. If it holds, it was likely a nuisance trip. If it trips again immediately, leave it off and call an electrician — a breaker that will not stay on is telling you something is wrong in that circuit.
Will it reconnect by itself when power returns?
Yes. Once grid voltage returns and stabilizes, the inverter runs through its reconnection checks and resumes feeding on its own. There is nothing to reset or acknowledge.
Need a professional?
This fault may need professional diagnosis. Contact a qualified solar electrician in your area.