Warning What does this mean?

Your system is down or running degraded, but this is not an immediate safety danger. Work through the safe steps below.

Solis Inverter OV-G-V Error — A Homeowner’s Troubleshooting Guide

Solis Inverter OV-G-V Error — A Homeowner’s Troubleshooting Guide

Your Solis inverter measured grid voltage above its safe limit and stopped feeding power to protect itself. That usually points to your local grid or the AC wiring between the inverter and the meter — not a broken inverter.

What should I do first?

Two quick questions — we'll point you to the right starting point.

Is this code still showing on your inverter's display?

What this code means

OV-G-V stands for over grid voltage. Your Solis inverter watches the AC voltage from the utility continuously, and the moment it climbs past the protection threshold, the inverter disconnects from the grid and raises this alarm. When voltage settles back into the normal range, it reconnects on its own. The four variants (01 through 04) cover different voltage levels and time windows, so noting exactly which one appears helps your installer understand what kind of event tripped it.

The important distinction with this code is where the high voltage comes from, because that decides who fixes it. In many cases the utility grid itself runs high, especially in suburbs with dense rooftop solar: on sunny middays every system exports at once and street-level voltage creeps upward. In other cases the grid is fine but the AC cable between your inverter and the switchboard is too thin or too long, so voltage at the inverter's terminals reads higher than what the meter sees. One is the distributor's network to address; the other is your installer's wiring to correct.

Related codes worth knowing: UN-G-V is the mirror image (voltage too low), and G-IMP (high grid impedance) often travels with OV-G-V, since pushing power through a high-impedance connection is itself a cause of local voltage rise. If your system logs more than one of these, mention all of them when you call.

What is this downtime costing you?

Rough estimate while your system isn't producing. Adjust the numbers to match your setup.

–per day
–per week
–per 30 days

≈ – kWh of lost production per day.

Estimate only — assumes ~80% real-world output vs. nameplate. Actual losses depend on weather, shading, panel direction, and your tariff.

Common causes

  • High midday solar export in your neighborhood pushing local grid voltage up. Streets with lots of rooftop systems often see voltage creep between late morning and mid-afternoon on sunny days.
  • Voltage rise inside your own AC cable. A thin or long run between the inverter and the switchboard means the inverter's terminals read higher than the grid actually is.
  • Protection limits set tighter than your local grid code allows. The inverter then trips on voltage the network considers perfectly normal.
  • A genuine utility overvoltage, such as a network tap-setting issue. If neighboring solar systems trip at the same times, the grid is the cause.
  • Brief spikes from network switching or large loads cycling nearby. These transient events are one reason the code has four variants.

Safe steps to try

Work top to bottom, ticking off each step as you complete it. 0 of 5 done.

Is your inverter still under warranty?

Before paying for a repair, check — your installer may fix this free.

Based on typical standard warranty terms — always confirm with your warranty card or installer paperwork, as terms vary by model, region, and purchase date.

When to call an electrician

Call your installer when the fault recurs across multiple days, when it clusters at the same time of day, or when you can see it eating into production. The technician's first job is to separate cable voltage rise from genuine grid overvoltage: they measure voltage at the inverter terminals and compare it with what the meter sees, check the AC cable's cross-section and run length against the installation spec, and review the protection settings against your local grid code. If the measurements show the grid itself running high, the installer escalates to the distribution company — and your log of dates, times, and variants becomes the evidence that gets action.

Frequently asked questions

Will OV-G-V damage my inverter?

No. The protection disconnects the inverter before voltage can do any harm, then reconnects automatically once voltage settles. The real cost of OV-G-V is lost generation, not damaged hardware.

Am I losing money while this keeps happening?

Yes, every trip is export you didn't sell or self-consume. A system that trips most sunny middays can lose a meaningful slice of its annual output, which is why recurring OV-G-V is worth fixing rather than tolerating.

Why does it always trip around the same time each day?

That pattern is the classic signature of export-driven voltage rise: every rooftop system on the street feeds at once and local voltage climbs. A time log showing this rhythm is exactly what your installer needs to see.

Can my installer just raise the voltage limit?

Only a professional, and only up to what your local grid code permits. More importantly, raising limits is pointless if the real problem is voltage rise in your own AC cable — that needs the cable checked, not the settings.

Need a professional?

This fault may need professional diagnosis. Contact a qualified solar electrician in your area.

Sources: meaning and troubleshooting verified against the manufacturer's documentation — Solis S5-GR3P(3-13)K Three Phase Inverter User Manual (Ginlong Solis), Table 9.1