How to Reset a Growatt Inverter Safely
A frozen display, a stuck WiFi connection, or an error code that refuses to clear — these are the everyday glitches a Growatt inverter owner runs into. In most cases a full shutdown and restart clears the temporary fault and brings the system back to normal. The catch is that the sequence matters: switching things off and on in the wrong order can leave the inverter in a half-powered state or fail to clear the fault at all.
Quick Answer
To reset a Growatt inverter, turn the DC isolator switch OFF first, then switch the solar AC isolator (or the labelled solar breaker in your switchboard) OFF. Wait at least five minutes until every LED and the display have gone completely dark. Then reverse the order: turn the DC switch back ON, followed by the AC isolator. Growatt’s own installation manuals describe this same shutdown and startup sequence — the inverter boots automatically once DC input voltage rises above its start threshold, runs its internal grid checks, and a solid green LED means it is generating again. The whole process takes about ten minutes.
Before You Reset: Safety Checks
Only ever touch isolators and breakers that are clearly labelled and that you are sure belong to your solar system. If you are unsure which breaker feeds the inverter, stop and call an electrician — guessing at a switchboard is how accidents happen. Never attempt a reset during a lightning storm, in wet conditions, or if you can see or smell anything wrong at the inverter, such as scorch marks or a burning smell. And never open the inverter casing: there are no user-serviceable parts inside, and doing so voids the warranty.
Do the reset during daylight hours. A Growatt inverter runs on DC power from your panels, so at night there is nothing to restart — all lights will be off and that is completely normal. Early to mid-morning is ideal: the panels are producing enough to wake the inverter, but the midday heat has not built up yet.
Step-by-Step Reset Procedure
This sequence follows the startup and shutdown sections of Growatt’s official installation manuals (including the MIN series and WIT series documents).
- Note any fault code first. Before powering down, read the display and write down the exact fault code and any message shown. If the fault returns after the reset, that code is what your installer will need.
- Hybrid models: switch the battery off. If your Growatt has a battery connected, turn the battery input switch (or the battery DC breaker) OFF, as described in the Growatt manual’s shutdown steps.
- Turn the AC isolator OFF. Find the solar AC isolator — usually beside the inverter or in your main switchboard — and switch it to OFF. You may hear a clunk from inside the inverter as the relays drop out.
- Turn the DC isolator OFF. The PV array DC isolator is typically a rotary switch under or beside the inverter. Turn it to OFF to disconnect the panels.
- Wait at least five minutes. Growatt’s manual instructs you to wait until the LED and OLED display have fully gone out. This lets the internal capacitors discharge completely, which is what actually clears a locked-up fault.
- Turn the DC switch back ON. Switch the DC isolator on first. The display may light up as the inverter wakes on panel power.
- Turn the AC isolator back ON. Reconnect the grid supply. The inverter will now run its startup routine.
- Give it time to synchronise. During startup the inverter checks its internal parameters and the grid’s voltage and frequency before exporting power. Allow one to three minutes — a solid green LED (or a normal generation reading on the display) confirms it is back in business.
What the Lights Mean After a Restart
A steady green LED is the sign you are looking for: the inverter is feeding power to the grid. A flashing green light during the first few minutes is the startup self-test — leave it alone and let it finish. If a red LED or a fault code appears instead, the reset did not clear the underlying problem; record the code and move to the “when to call a professional” section below rather than restarting again and again.
When a Reset Won’t Help
Repeated resets cannot fix a hardware fault, a wiring problem, or a grid issue. If the same error code reappears within minutes of a restart, the inverter is telling you the root cause is still present — treat that as information, not as an invitation to keep cycling the power. Likewise, a reset does nothing for monitoring problems where the inverter is generating fine but the ShinePhone app shows no data; that is a WiFi dongle issue, not an inverter fault.
When to Call a Professional
Call your installer or a licensed solar technician if any of these apply:
- The same fault code returns after two properly performed resets.
- The AC breaker trips again as soon as you switch it back on — do not keep resetting a tripping breaker; call an electrician.
- You see physical damage, water ingress, melted plastic, or smell burning at any point — switch everything off and call immediately.
- The inverter will not wake up at all during daylight after a correct restart sequence.
- You are unsure which isolator or breaker belongs to the solar system.
Frequently Asked Questions
Will resetting my Growatt erase its settings or generation history?
No. A shutdown and restart does not change country/grid settings, WiFi configuration, or the lifetime energy counters stored in the inverter. Those are only affected by a factory reset, which is a separate installer-level procedure you should not perform yourself.
How often is it safe to restart the inverter?
Occasional restarts to clear temporary faults are harmless. If you find yourself restarting weekly or daily, something deeper is wrong — repeated cycling stresses relays and breakers, so book a service visit instead.
My inverter shows no lights at night. Should I reset it?
No. A Growatt inverter is powered by its DC panels, so at night the unit is completely off and the app may show zero production. That is normal operation. Only reset during daylight when the inverter should be awake but isn’t.
Does a reset fix WiFi and ShinePhone app problems?
Sometimes — a restart reboots the monitoring dongle too. But if the inverter itself is generating normally (green LED solid) while the app shows no data, check your home WiFi and the dongle’s own LEDs first before cycling the inverter’s power.
Related Error Codes
- Growatt Error 102 — AC voltage out of range, a common cause of repeated shutdowns
- Growatt Error 117 — relay or grid-connection fault that a reset may temporarily clear
Sources: Growatt MIN series installation manual (Section 8, Startup and Shutdown the inverter); Growatt WIT series user manual (AFCI alarm clearing and restart procedure); Growatt single-phase inverter operation manual.
Need a professional?
If you're unsure about any step above — especially anything involving your breaker panel, wiring, or opening equipment — contact a qualified solar installer or electrician. It's always cheaper than a mistake.