SolarEdge

SolarEdge Error Codes

21 diagnostic articles for SolarEdge inverters — verified against manufacturer documentation.

SolarEdge Inverter 8X19–8X1B AC Voltage Too High on Lines 1–3
Warning

SolarEdge Inverter 8X19–8X1B AC Voltage Too High on Lines 1–3

SolarEdge codes 8X19, 8X1A, and 8X1B mean "AC Voltage Too High" on line 1,…

Read diagnosis →
SolarEdge Inverter Error 2X13 — Practical Steps to Fix It Safely
Warning

SolarEdge Inverter Error 2X13 — Practical Steps to Fix It Safely

SW Error is an internal software fault in your SolarEdge inverter — it appears…

Read diagnosis →
SolarEdge Inverter Error 8X52 — Causes and Safe Fixes
Warning

SolarEdge Inverter Error 8X52 — Causes and Safe Fixes

Unbalanced DC Voltage (code 8x52) means the inverter detected abnormal voltage imbalance on the…

Read diagnosis →
SolarEdge Inverter Error 8X10 — What It Means & What to Check
Warning

SolarEdge Inverter Error 8X10 — What It Means & What to Check

The inverter's internal processor lost contact with its own sub-components, so it stopped producing…

Read diagnosis →
SolarEdge Inverter Error 8X19 — Causes and Safe Fixes
Warning

SolarEdge Inverter Error 8X19 — Causes and Safe Fixes

The grid voltage on the indicated line rose above your country's permitted limit, so…

Read diagnosis →
SolarEdge Inverter Error 8X58 — When to Call an Electrician
Critical

SolarEdge Inverter Error 8X58 — When to Call an Electrician

The insulation resistance between your PV array and earth dropped below the safe limit…

Read diagnosis →
SolarEdge Inverter Temperature Too High — Why It Overheats
Warning

SolarEdge Inverter Temperature Too High — Why It Overheats

Your inverter ran hotter than its safe operating limit and protected itself — it…

Read diagnosis →
SolarEdge Inverter Fan Failure — Why the Fan Stops and What to Do
Warning

SolarEdge Inverter Fan Failure — Why the Fan Stops and What to Do

One of your inverter's cooling fans has stopped working. This is a warning rather…

Read diagnosis →
SolarEdge Inverter Error 8X1C — Why It Happens and How to Respond
Warning

SolarEdge Inverter Error 8X1C — Why It Happens and How to Respond

The grid voltage on the indicated line dropped below the permitted minimum, so your…

Read diagnosis →
SolarEdge Inverter Error 18XA6 — Practical Steps to Fix It Safely
Warning

SolarEdge Inverter Error 18XA6 — Practical Steps to Fix It Safely

Your inverter's built-in self-check found an internal hardware fault, so it has stopped producing…

Read diagnosis →
1 2 3